2gig Technologies 2GIG-BRDG1-900 Petunjuk Instalasi
Jelajahi secara online atau unduh pdf Petunjuk Instalasi untuk Router Jaringan 2gig Technologies 2GIG-BRDG1-900. 2gig Technologies 2GIG-BRDG1-900 4 halaman. Go!bridge ip communicator
2GIG-BRDG1-900
GO!BRIDGE IP COMMUNICATOR
INSTALLATION INSTRUCTIONS
The Go!Bridge IP Communicator™ (2GIG‐BRDG1‐900) provides Internet
connectivity between the monitoring service's Central Station and the
Go!Control® Panel, when the panel is used as a household burglar alarm
system.
It supports automatic firmware updates, provides interactive security
services, and increases supervision using signal‐forwarding to the Central
Station. For wireless communication with the Control Panel, the 900MHz
Transceiver Module (2GIG‐XCVR) must be installed in the panel. For
Internet access, the Go!Bridge must be connected to the local network
router using an Ethernet cable (not provided).
Contents
Verify that the package includes the following:
•
1—Go!Bridge IP Communicator
•
1—5VDC USB Mini‐B Power Supply
•
1—Stand
•
1—Plastic Power Supply Bracket (includes Self‐Adhesive Backing
and Zip Tie)
•
1—Wall Socket Screw for Power Supply Bracket
•
2—Phillips Head Screws and Wall Anchors (to mount unit on wall)
•
4—Self‐Adhesive Vinyl Bumpers for use on unit or stand
Requirements
Before you install, program, and test the Go!Bridge IP Communicator,
ensure the control panel being paired with the Go!Bridge IP
Communicator meets these requirements:
•
Firmware Version 1.12 (or higher)
•
2GIG‐XCVR 900 MHz Transceiver
For compliance with UL 1023: Household Burglar‐
IMPORTANT:
Alarm System Units, the Go!Bridge must be installed in the
same room as the Internet modem or router.
NOTE: To protect data sent via the local wireless network, it is
recommended that you install the Go!Bridge IP Communicator on
a local network where either WPA (Wi‐Fi Protected Access) or
WPA2 (Wi‐Fi Protected Access II) encryption is already enabled.
After installing, programming, and testing the Go!Bridge IP
Communicator, you will need to register a new customer with the third‐
party monitoring service. See Registration on page 3.
Figure 1 Go!Bridge Front View—LED Indicators and Learn Button
A Network LED
B 900 MHz LED
C Learn Button
Powering ON the Go!Bridge IP Communicator
Use these steps to power ON the Go!Bridge IP Communicator:
1
Attach the power supply to the bracket (provided) as follows:
1a Insert the power supply into the enclosure on the plastic bracket.
See C in the figure below.
1b Secure the power supply to the retaining bracket by threading a
zip tie through the bracket's slots. See D in the figure below.
1c Remove the strip from the self‐adhesive backing on the power
supply bracket.
1d Affix the adhesive on the bracket to the wall outlet. Then secure
the bracket to the outlet with the wall socket screw (provided).
NOTE: Always use the provided power supply bracket in the United
States (and other countries where it is required). Canada does not
require the power supply retaining bracket.
Figure 2 Power Supply and Bracket
A 110V Wall Outlet
B
Plastic Power Supply Bracket with Adhesive Backing
C
AC Power Supply
D Zip Tie
2
Connect the Go!Bridge to the power source.
NOTE: Do not connect an Ethernet cable to the Go!Bridge IP
Communicator at this time. You will connect the cable when
completing the steps in Programming the Go!Bridge IP
Communicator into the Control Panel.
3
(Optional) Place the stand (provided) on a counter, desktop, or other
flat surface. Set the Go!Bridge IP Communicator in the stand.
NOTE: To protect surfaces from damage, affix the self‐adhesive vinyl
bumpers to the unit or stand.
4
Verify that the two (2) LEDs on the Go!Bridge IP Communicator
illuminate in RED. See Figure 1 Go!Bridge Front View—LED Indicators
and Learn Button on page 1.
Copyright © 2014 Linear LLC
1