The both modules are installed in 16-slot 3U-high chassis, but only the host-site
chassis is equipped with network management module. The remote-site module
shall be set to "forced remote network management mode". That is to say, the 8
switch shall be turned to ON.
4.1
Inspect after Opening
Please first check if the models and part numbers are in consistence, and also check if the
equipments are damaged.
4.2
Preparation before Installation
•
Carefully read this manual
•
Prepare all kinds of the cable. Ensure that they are not short-circuited. Refer to
Appendix A for cable making.
•
Ensure the pressure of power supply is in the tolerance range, the chassis is well
connected with the ground.
•
Prepare the BERT and optical power meter for test of line quality.
•
Place the equipment at stable and secure environment. Pay attention to the
requirements of the ambience.
4.3
Installation
This module can be installed into Dynamix's dedicated 16-slot 3U-high chassis, 4-slot
1 U-high chassis, and single slot chassis. Slowly insert the module into the slot to the end,
and fasten the fixing screw tightly.
4.3.1
Connecting the Cables
•
E1 Interface:
RJ45 socket, 120 Ohm balanced signal.
4. Installation and Test
Dynamix Co., Ltd
th
- 7 -