Autonics KN-2000W Series Panduan Produk - Halaman 6
Jelajahi secara online atau unduh pdf Panduan Produk untuk Alat Ukur Autonics KN-2000W Series. Autonics KN-2000W Series 6 halaman. 1-channel digital temperature indicators
Function: High / Low-limit scale value
This function is to display setting of particular high / low-limit value in order to
display high / low-limit value of measured input.
If measured inputs are a and b and particular values are A and B, it will display a = A,
b = B as below graphs.
Display
Display
value
value
B
A
a
b
Input
value
Display
Display
value
value
B
a
b
a
Input
value
A
Function: Alarm
Set both alarm operation and alarm option by combining.
88* 8
Each alarm operates individually in two alarm output models.
Alarm
Alarm
When the current temperature is out of alarm range, alarm clears
operation
option
automatically.
■ Operation
Name
Alarm operation
-
-
OFF
H
ON
Absolute
value high
PV
90℃
limit
Absolute value: Set as 90℃ Absolute value: Set as 110℃
ON
H
OFF
Absolute
value low
PV
limit
90℃
Absolute value: Set as 90℃ Absolute value: Set as 110℃
Sensor break -
■ Option
Name
Description
Standard
If it is an alarm condition, alarm output is ON. If it is a clear alarm
alarm
condition, alarm output is OFF.
If it is an alarm condition, alarm output is ON and maintains ON
Alarm latch
status.
First alarm condition is ignored and from second alarm
Standby
condition, standard alarm operates. When power is supplied
sequence
and it is an alarm condition, this first alarm condition is ignored
and from the second alarm condition, standard alarm operates.
Alarm
If it is an alarm condition, it operates both alarm latch and
latch and
standby sequence. When power is supplied and it is an alarm
standby
condition, this first alarm condition is ignored and from the
sequence
second 1alarm condition, alarm latch operates.
Segment Table
The segments displayed on the product indicate the following meanings. It may differ
depending on the product.
7 Segment
11 Segment
0
I
0
0
I
0
I
1
J
1
1
J
1
J
2
K
2
2
K
2
K
3
L
3
3
L
3
L
4
M
4
4
M
4
M
5
N
5
5
N
5
N
6
O
6
6
O
6
O
7
P
7
7
P
7
P
8
Q
8
8
Q
8
Q
9
R
9
9
R
9
R
A
S
A
A
S
A
S
B
T
B
B
T
B
T
C
U
C
C
U
C
U
D
V
D
D
V
D
V
E
W
E
E
W
E
W
F
X
F
F
X
F
X
G
Y
G
G
Y
G
Y
H
Z
H
H
Z
H
Z
Display
value
B
B
A
a
b
Input
A
a
b
Input
value
value
B
b
Input
A
value
• H: Alarm output hysteresis
Description
No alarm output
OFF
H
ON
If PV is higher than the
PV
absolute value, the output
110℃
will be ON.
ON
H
OFF
If PV is lower than the
absolute value, the output
PV
110℃
will be ON.
It will be ON when it detects
sensor disconnection.
Condition
of re-apply
-
-
Power ON
12 Segment
16 Segment
I
0
I
0
0
I
0
I
J
1
J
1
1
J
1
J
K
2
K
2
2
K
2
K
L
3
L
3
3
L
3
L
M
4
M
4
4
M
4
M
N
5
N
5
5
N
5
N
O
6
O
6
6
O
6
O
P
7
P
7
7
P
7
P
Q
8
Q
8
8
Q
8
Q
R
9
R
9
9
R
9
R
S
A
S
A
A
S
A
S
T
B
T
B
B
T
B
T
U
C
U
C
C
U
C
U
V
D
V
D
D
V
D
V
W
E
W
E
E
W
E
W
X
F
X
F
F
X
F
X
Y
G
Y
G
G
Y
G
Y
Z
H
Z
H
H
Z
H
Z
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
18, Bansong-ro 513Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002