Ordering Information
This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website.
CT
❶
❷
-
❶ Display digits
4: 4-digit
6: 6-digit
❷ Size
S: DIN W 48 × H 48 mm
Y: DIN W 72 × H 36 mm
M: DIN W 72 × H 72 mm
Manual
For proper use of the product, refer to the manuals and be sure to follow the safety
considerations in the manuals.
Download the manuals from the Autonics website.
Dimensions
• Unit: mm, For the detailed drawings, follow the Autonics website.
■ CTS
□48
■ CTY
72
■ CTM
□72
■ Bracket
• CTS
□49.5
30.5
60.3
■ Panel cut-out
A
C
Find Quality Products Online at:
❸
❹
❺
❸ Output
1P: 1-stage preset
2P: 2-stage preset
I: indicator
❹ Power supply
2: 24 VACᜠ ± 10 % 50 / 60 Hz,
24 - 48 VDCᜡ ± 10 %
4: 100 - 240 VACᜠ ± 10 % 50 / 60 Hz
❺ Communication
No mark: none
T: RS485 communication output
10
90
6
77
10
85
• CTY
60
• CTM
68
A
B
C
CTS
≥ 65
≥ 65
45
+0.6
0
CTY
≥ 91
≥ 40
68
+0.7
0
CTM
≥ 91
≥ 91
68
+0.7
0
GlobalTestSupply
www.
Unit Descriptions
• CTS
6
3
7
8
9
10
• CTY
7
4
5
3
6
2
No.
Part name
Counting value
1
display part (red)
Setting value
2
display part (green)
3
Key LOCK indicator
4
Counter indicator
5
Timer indicator
Preset value checking,
6
changing indicator
7
Output indicator
8
RESET key
9
MODE key
10
Setting key
11
BATCH key
BATCH output
12
indicator (red)
BATCH setting value
13
checking, changing
indicator (green)
Connections
• Counter operation: If INHIBIT signal is applied, count input will be prohibited.
Timer operation: If INHIBIT signal is applied, time progressing will stop.(HOLD)
• SOURCE: 100 - 240 VACᜠ 50 / 60 Hz 12 VA
24 VACᜠ 50 / 60 Hz 10 VA, 24 - 48 VDCᜡ 8 W
■ CTS
• 1-stage preset, standard model (CT□S-1P□)
12 VDCᜡ 100 mA
INB / INH
INA
0 VDCᜡ
6
7
8
9
11
OUT
1
2
3
4
N.O.
COM
N.C.
250 VACᜠ 5 A,
30 VDCᜡ 5 A
RESISTIVE LOAD
SOURCE
• 2-stage preset, standard model (CT□S-2P□)
12 VDCᜡ 100 mA
INB / INH
INA
0 VDCᜡ
6
7
8
9
4.4
11
1
2
3
4
OUT1
OUT2
250 VACᜠ 5 A,
30 VDCᜡ 5 A
RESISTIVE LOAD
SOURCE
• Indicator, standard model (CT6S-I□)
12 VDCᜡ 100 mA
INB / INH
INA
0 VDCᜡ
D
6
7
8
9
45
+0.6
0
11
31.5
+0.5
0
68
1
2
3
4
+0.7
0
SOURCE
• CTM
1
2
5
6
4
13
3
7
8
8
11
9
10
9
1
Name
Function
plate
RUN mode: Displays counting value, time progress
-
value
Parameter 1, 2 group: Displays setting item
RUN mode: Displays setting value
-
Parameter 1, 2 group: Displays setting content
LOCK
Turns ON for key LOCK setting
CNT
Turns ON for counter operation
In timer operation -
TMR
Flashes: time progress / turns ON: stopping time
PS1,
Turns ON when checking and changing preset value
PS2
OUT1,
Turns ON for the dedicated control output ON
OUT2
[RST]
Counting value RESET, BATCH counting value RESET
RUN mode ↔ Parameter 1, 2 group
[MD]
Move to the next when the parameter setting
[◀]
Enter preset value change mode and move digits
Preset value of preset value change mode and setting
[▼], [▲]
content of parameter 1, 2 group
Enter function setting check mod and move check items
[BA]
Enter BATCH counter indication mode
BA.O
Turns ON when BATCH output ON
Turns ON when checking and changing BATCH setting
BA.S
value
• 1-stage preset, comm. model (CT□S-1P□T)
12 VDCᜡ 100 mA
RESET
INB / INH
INA
0 VDCᜡ
10
6
7
8
OUT
30 VDCᜡ
12
11
A(+)
RS485
OUT
100 mA
5
1
2
3
N.O.
COM
N.C.
250 VACᜠ 5 A,
30 VDCᜡ 5 A
RESISTIVE LOAD
SOURCE
• 2-stage preset, comm. model (CT□S-2P□T)
12 VDCᜡ 100 mA
RESET
INB / INH
INA
0 VDCᜡ
10
6
7
8
OUT2
30 VDCᜡ
12
A(+)
11
RS485
100 mA
5
1
2
3
OUT1 OUT2
250 VACᜠ 5 A,
30 VDCᜡ 5 A
RESISTIVE LOAD
• Indicator, comm. model (CT6S-I□T)
12 VDCᜡ 100 mA
RESET
INB / INH
INA
0 VDCᜡ
6
7
8
10
11
A(+)
RS485
12
1
2
3
5
.com
1
2
5
4
12
10
RESET
9
10
B(-)
12
4
5
RESET
9
10
B(-)
12
4
5
SOURCE
RESET
9
10
B(-)
12
4
5
SOURCE