Autonics FXM Series Panduan Produk - Halaman 5
Jelajahi secara online atau unduh pdf Panduan Produk untuk Pengatur waktu Autonics FXM Series. Autonics FXM Series 5 halaman. Digital counters/timers
■ Output operation mode
• Output type
OUT1' One-shot output (0.5 sec fixed)
Retained (hold) output
OUT2' One-shot output
• Set OUT2' One-shot output time via [TIME] volume switch on the front side.
setting range: 0.05 to 5 sec
Output operation description in input operation mode
Mode
Up, Up / Down - A, B, C
RESET
2-stage setting
1-stage setting
0
F
OUT1
OUT2 (OUT)
After count-up, counting display value increases or decreases until RESET input is applied
and retained (hold) output is maintained.
RESET
2-stage setting
1-stage setting
0
N
OUT1
OUT2 (OUT)
After count-up, counting display value and retained (hold) output are maintained until
RESET input is applied.
RESET
2-stage setting
1-stage setting
0
OUT1
C
OUT2 (OUT)
When count-up, counting display value is RESET and it counts simultaneously.
OUT1 retained (hold) output turns OFF after OUT2 One-Shot output time.
• One-Shot output time of OUT1 is independent of OUT2 output.
RESET
2-stage setting
1-stage setting
0
OUT1
R
OUT2 (OUT)
After count-up, counting display value is reset after one-shot output time of OUT2
and it counts simultaneously.
OUT1 retained (hold) output turns OFF after OUT2 One-Shot output time.
• One-Shot output time of OUT1 is independent of OUT2 output.
RESET
2-stage setting
1-stage setting
0
OUT1
K
OUT2 (OUT)
After count-up, counting display value increases or decreases until RESET input is applied.
OUT1 retained (hold) output turns OFF after OUT2 One-Shot output time.
• One-Shot output time of OUT1 is independent of OUT2 output.
RESET
2-stage setting
1-stage setting
0
OUT1
OUT2 (OUT)
P
After count-up, counting display value is maintained while OUT2 output is ON, and
internally RESET and it counts simultaneously.
When OUT2 output is OFF, displays counting value while OUT2 output is ON, and it
increases or decreases.
OUT1 retained (hold) output turns OFF after OUT2 One-Shot output time.
• One-Shot output time of OUT1 is independent of OUT2 output.
RESET
2-stage setting
1-stage setting
0
OUT1
Q
OUT2 (OUT)
After count-up, counting display value increases or decreases during One-shot output time
of OUT2.
OUT1 retained (hold) output turns OFF after OUT2 One-Shot output time.
• One-Shot output time of OUT1 is independent of OUT2 output.
Output operation description in input operation mode
Mode
Up
RESET
2-stage setting
1-stage setting
0
S
OUT1
OUT2 (OUT)
OUT1 / 2 maintains ON when counting
display value ≥ 1 / 2-stage setting value.
Output operation description in input operation mode
Mode
Up / Down - A, B, C
RESET
2-stage setting
1-stage setting
0
S
OUT1
OUT2 (OUT)
OUT1 / 2 maintains ON when counting
display value ≥ 1 / 2-stage setting value.
Retained (hold) output
Down, Up / Down - D, E, F
RESET
2-stage setting
1-stage setting
0
OUT1
OUT2 (OUT)
RESET
2-stage setting
1-stage setting
0
OUT1
OUT2 (OUT)
RESET
2-stage setting
1-stage setting
0
OUT1
OUT2 (OUT)
RESET
2-stage setting
1-stage setting
0
OUT1
OUT2 (OUT)
RESET
2-stage setting
1-stage setting
0
OUT1
OUT2 (OUT)
RESET
2-stage setting
1-stage setting
0
OUT1
OUT2 (OUT)
RESET
2-stage setting
1-stage setting
0
OUT1
OUT2 (OUT)
Down
RESET
2-stage setting
1-stage setting
0
OUT1
OUT2 (OUT)
OUT1 / 2 maintains ON when counting
display value ≤ 1 / 2-stage setting value.
Up / Down - D, E, F
RESET
2-stage setting
1-stage setting
0
OUT1
OUT2 (OUT)
OUT1 / 2 maintains ON when counting
display value ≤ 1 / 2-stage setting value.
■ Counting operation (for indicator model)
Input operation mode = Up
RESET
+Max.
display value
0
Input operation mode = Up / Down - A, B, C Input operation mode = Up / Down - D, E, F
RESET
+Max.
display value
0
-Max.
display value
Timer Operation
■ Output operation mode
• Output type
OUT1' One-shot output (0.5 sec fixed)
Retained (hold) output
Output operation description in input operation mode
Mode
Up, Up / Down - A, B, C
RESET
2-stage setting
1-stage setting
0
S
OUT1
OUT2 (OUT)
Output turns OFF → ON → OFF repeatedly (flicker).
■ Time operation (for indicator model)
Input operation mode = Up, Up / Down - A, B, C Input operation mode = Down, Up / Down - D, E, F
RESET
INHIBIT
+Max.
display value
0
Segment Table
The segments displayed on the product indicate the following meanings. It may differ
depending on the product.
7 segment
11 segment
0
I
0
0
0
I
1
J
1
1
1
J
2
K
2
2
2
K
3
L
3
3
3
L
4
M
4
4
4
M
5
N
5
5
5
N
6
O
6
6
6
O
7
P
7
7
7
P
8
Q
8
8
8
Q
9
R
9
9
9
R
A
S
A
A
A
S
B
T
B
B
B
T
C
U
C
C
C
U
D
V
D
D
D
V
E
W
E
E
E
W
F
X
F
F
F
X
G
Y
G
G
G
Y
H
Z
H
H
H
Z
18, Bansong-ro 513Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002
www.autonics.com | +82-51-519-3232 | [email protected]
Input operation mode = Down
RESET
+Max.
display value
0
-Max.
display value
RESET
+Max.
display value
0
-Max.
display value
Retained (hold) output
Down, Up / Down - D, E, F
RESET
2-stage setting
1-stage setting
0
OUT1
OUT2 (OUT)
RESET
INHIBIT
+Max.
display value
0
-Max.
display value
12 segment
16 segment
I
0
I
0
I
0
I
0
I
J
1
J
1
J
1
J
1
J
K
2
K
2
K
2
K
2
K
L
3
L
3
L
3
L
3
L
M
4
M
4
M
4
M
4
M
N
5
N
5
N
5
N
5
N
O
6
O
6
O
6
O
6
O
P
7
P
7
P
7
P
7
P
Q
8
Q
8
Q
8
Q
8
Q
R
9
R
9
R
9
R
9
R
S
A
S
A
S
A
S
A
S
T
B
T
B
T
B
T
B
T
U
C
U
C
U
C
U
C
U
V
D
V
D
V
D
V
D
V
W
E
W
E
W
E
W
E
W
X
F
X
F
X
F
X
F
X
Y
G
Y
G
Y
G
Y
G
Y
Z
H
Z
H
Z
H
Z
H
Z
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z