When water comes in direct contact with a
WaterHound sensor, an RF (radio frequency) signal is
transmitted to the WaterCop
turning off the water source to protect the building from
additional water damage. The red indicator light will
signal that the valve is now in the closed position, and
that you need to check all areas where you have
placed a WaterHound to determine what plumbing
product caused the system to activate. The valve will
remain closed until the unit is reset on the WaterCop
panel. After the plumbing problem is fixed, reset the
®
WaterCop
by pressing "open valve" (green circle) on
the face of the WaterCop
indicator will be lit. See illustration to the lower left.
Note: If major repairs are needed to correct the
plumbing system, it is recommended that the manual
shut-off valve upstream of the WaterCop
closed during the repairs. Close the main water shut-
off valve and unplug the WaterCop
repairs on the plumbing system.
Note:
In case of a power failure, the WaterCop
cannot operate. If the power is out, you will need to use
the manual shut-off valve to turn the water off in case
of an emergency.
When power is restored, the
®
WaterCop
will remain in its last known position indi-
cated by the red or green lights on the face of the unit.
®
WaterCop
Specifications
Max. working pressure ...125 PSIG
Ambient temperature .....35° to 105° F
Enclosure .......................Polycarbonate
Voltage ...........................115, 1 Phase, 60 Hz
Current ...........................2.5 Amps
Power Input:
Standby ..........................1.375 W
Holding (2.5 sec) ............75 W
Power Cord ....................8 ft. Heavy-Duty Grounded
Valve ..............................Full-Port, Brass, NPT
Valve Seals ....................RTFE
Flow Data
Valve Size Cv = Gpm flow @ 1 PSI pressure drop
1/2" NPT
19
3/4" NPT
34
1" NPT
52
For cold water applications.
®
and the valve closes,
®
. Valve will open and green
®
also be
®
before doing

FCC Information

This equipment has been tested and found to comply
within limits of a class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful
interference in a residential installation.
equipment generates, uses, and can radiate radio
frequency energy and if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation.
The water sensors only transmit a radio signal during
testing and when contact is made between the probes
as when water is detected. This signal is of a 2-second
duration and is repeated approximately every 6
seconds while activated. This 2 second signal should
be the only time potential interference could be
detected. If you suspect the unit is interfering with your
radio and/or television reception on a prolonged basis,
remove batteries from all transmitters to determine if
this unit is causing the interference. If so, please
consult your dealer.
®

LIMITED WARRANTY

DynaQuip
Controls
®
WaterCop
to be free from defects in material and
workmanship under normal use and if properly
installed for a period of three years from the date of
purchase. If found to be defective as mentioned above,
it will be replaced or repaired if returned prepaid along
with proof of date of purchase. This shall constitute the
sole remedy of the purchaser and the sole liability of
DynaQuip Controls Corporation. To the extent
permitted by law, the foregoing is exclusive and in lieu
of all other warranties or representations whether
expressed or implied, including any implied warranty of
®
merchantability or fitness. In no event shall DynaQuip
Controls Corporation be liable for special or
consequential damages.