R E P L A C I N G T H E B A L L A S T
1
1. Disconnect power at the breaker or
fuse panel before servicing unit.
2
2. Open the ballast housing by removing the
four (4) screws then removing the cover.
3
3. Disconnect all ballast wiring by pressing
down on connector tabs and pulling wire
straight out.
CAUTION: Never attempt to check operation of the ActivePure® cell(s) by direct
observation. Severe eye damage can result. Use the indicator lamps on the
bottom of the ballast only.
CAUTION: Disconnect power at the breaker or fuse panel before servicing unit. Always
follow OSHA lockout procedures to prevent accidental exposure to electrical energy.
14
4
4. Remove the two (2) nuts
securing ballast to the case.
Remove the ballast.
5
5. Place new ballast into original
location and secure using the
two (2) nuts removed in step 4.
R E P L A C I N G T H E B A L L A S T
A
LED+ LED- RED RED BLUE BLUE
B
6
6. To reconnect wiring, (A) press each tab on the ballast and insert wire. (B)
Release tab and gently pull wire to ensure it is properly locked into place.
UPPER (6 terminals)
• Black LED wire in LED+
• White LED wire in LED-
• 2 Blue wires in BLUE
• 2 Red wires in RED
14
7
7. Replace cover and secure with
the original four (4) screws.
( co nt i n u e d )
BLACK WHITE GREEN
LOWER (3 terminals)
• Black power wire in BLACK
• White power wire in WHITE
• GREEN is not used
LED INDICATOR
8
8. Re-install unit if removed from duct.
Reconnect power and check for
proper operation (LED indicator
should be lit when in operation).