969.Coffee Artika Manual - Halaman 7

Jelajahi secara online atau unduh pdf Manual untuk Pembuat Kopi 969.Coffee Artika. 969.Coffee Artika 7 halaman.

969.Coffee Artika Manual
If the filter is clogged or deteriorated, contact the after-sales service center for its replacement.
The group shower heads and wands must also be cleaned by using a sponge and hot water.
Troubleshooting
If all the LED flash at the same time, the control unit is signaling a problem.
The most important cases include:
• pump running time has exceeded 2 minutes while filling the boiler. This is usually due to:
-
no water arriving;
-
the level regulator malfunctioning
• Water does not flow during dispensing for more than 30 seconds. This is usually due to:
-
no water in the hydraulic circuit
-
clogged jet;
-
faulty volumetric meter
-
unsuitable grinding (too fine)
Turn off the machine. Do not attempt to repair
Filling the boiler
A probe located inside the boiler controls the water level.
Based on the water level, the pump will turn on and off but only after a certain delay in order to prevent continuous
operations due to the oscillation of water level.
Machine failure
Contact the technical assistance centre
Accessories
The machine is supplied with a filling tube and drainage tube with relative clamps, blind filter and brush for daily
cleaning, together with filter holders and filters.
Warranty
The warranty expired after 12 months from the purchasing date. It covers the mechanical parts and includes the spare
parts.
It shall be null and void if the machine is improperly used or unauthorized personnel have tampered with it.
7