Autonumis WRCBS600 Panduan Instalasi Pengguna - Halaman 3

Jelajahi secara online atau unduh pdf Panduan Instalasi Pengguna untuk Pembeku Autonumis WRCBS600. Autonumis WRCBS600 13 halaman. Popular & premier cooler, single integral unit

Installation

Store the unit upright. If the unit has been stored or transported on its back, front
or sides then it must be placed upright for at least an hour before switching on.
Place the unit on an even floor as far away as possible from any source of heat.
Note: Do not move unit by lifting either the door or door handle as this may
cause damage to the cabinet.
Please ensure the correct aperture size is made available for this unit:
Space Required
All dimensions exclude door handle
Single Unit
Unit Dimensions
All dimensions exclude door handle
Single Unit

General Operation

The cabinet door should remain firmly closed during normal operation. This
prevents warm moist air entering and creating frost within the cabinet. If the
cabinet is left open for extended periods ice will form. This will prevent cooling
and the machine will then require defrosting (see page 03).
The unit should be left switched on, and should not be switched off between
trading sessions. The unit is designed to operate in an ambient temperature
range of 6°C -25°C, however for short periods of time (up to 8 hours) the unit
will operate normally at 32°C. The cabinet is designed to chill product in sealed
containers only i.e. bottles, cans etc. It is not recommended that glasses of
drink or similar are placed in the unit for cooling.
Height
Width
925mm
530mm
Height
Width
900mm
525mm
Depth
The correct aperture size should
give a gap of approximately 25mm
525mm
between the top of the cabinet and
the underside of the back bar and
between the back of the unit and
the wall. Poor ventilation due to
insufficient aperture size is likely to
cause: reduced cooling; Icing up;
Depth
Premature compressor failure.
500mm
02