High Sec Labs FVCE11PH-M Panduan Pengaturan Cepat - Halaman 8

Jelajahi secara online atau unduh pdf Panduan Pengaturan Cepat untuk Pemanjang High Sec Labs FVCE11PH-M. High Sec Labs FVCE11PH-M 9 halaman. Secure kvm extenders

Table of Contents
SECTIONS

OPERATION

Running an EDID Capture
Before using the Extender, run a one-time EDID capture on both sides – Transmitter
and Receiver. This prevents the continuous transfer of potentially malicious data -
from the display to the PC – that could infect the PC, cause data leakage, and so on.
Preparation:
Connect the PC and all peripherals to both the units, according to the
Installation Instructions.
Make sure the PC, display, and the units are ON.
To run an EDID capture:
1.
On the Transmitter, short-click the EDID Lock button – for less than one
second.
Warning: Long-clicking the EDID Lock button sends the unit into an
undesired loop. If this happens, restart the unit and repeat the
procedure.
At first, the EDID LED flickers for a few seconds and then, once captured
lights green continuously.
2.
Make same on the Receiver, short-click the EDID Lock button – for less
than one second and wait until the EDID LED will light green continuously.
Note: If the EDID LED is OFF, check the connections and that the PC or
the Display are powered ON. Then, repeat the procedure.
3. Restart both units.
HSL Secure Extended Isolators Quick Setup Guide
1
2
EDID Lock button
3
Note: An EDID capture needs to be
performed for new installations and
when changing a display.
EDID LED
Transmitter
EDID LED
HDC19956 Rev.1.0
Receiver
8