Emerson FB1200 Manual Penggantian Lapangan - Halaman 4

Jelajahi secara online atau unduh pdf Manual Penggantian Lapangan untuk Alat Ukur Emerson FB1200. Emerson FB1200 8 halaman. Flow computer coin cell battery field
Juga untuk Emerson FB1200: Manual Penggantian Bidang Papan Pemutusan Hubungan Kerja (18 halaman), Manual Penggantian (18 halaman), Manual Penggantian Lapangan (14 halaman), Manual Penggantian Lapangan (20 halaman), Manual Penggantian Lapangan (8 halaman), Manual Penggantian (8 halaman)

Emerson FB1200 Manual Penggantian Lapangan
FB1100/FB1200 Flow Computer End Cap Field Replacement Guide
D301814X012
November 2020
Removing/Tightening the End Cap with long screwdriver
Note
If you need more leverage, place a long screwdriver or other appropriate tool across the two notches
in the end cap to act as a pry bar.
Removing/Replacing the Retaining Clamp on End Caps
For flameproof ATEX/IEC applications, each end cap includes a retaining clamp which screws down
to prevent the end cap from being unscrewed.
Front End Cap with Retaining Clamp Fitted
1
2
3
Retaining Clamp in Place
To loosen or tighten the screw, use a 3mm hexagonal wrench. When tightening, torque to 10 to 12
in-lbs (1.1 to 1.4 N-m).
2
End Cap
Screw
Retaining Clamp