Autopilot POOL PILOT SOFT TOUCH Lembar Petunjuk Pengoperasian, Pemecahan Masalah, dan Teknis - Halaman 4

Jelajahi secara online atau unduh pdf Lembar Petunjuk Pengoperasian, Pemecahan Masalah, dan Teknis untuk Peralatan Pencahayaan Autopilot POOL PILOT SOFT TOUCH. Autopilot POOL PILOT SOFT TOUCH 6 halaman.

MAXIMUM CELL CURRENT (DC AMPS)
Cell Power 1 = 5 AMPS
Cell Power 2 = 6.5 AMPS
Cell Power 3 = 8 AMPS
WARNING: Operating on level "1" reduces cell power but extends cell life, operating on level "3" increases cell
power but shortens cell life
REVERSAL TIME
SHORT = Every 2 hours of cell run time
NORM = Every 4 hours of cell run time
LONG = Every 8 hours of cell run time
NOTE:
REVERSING AND BOOST CYCLE TIMES ARE STORED WHEN POWER GOES OFF, RESTARTING AT THE
SAME POINT IN THEIR CYCLE.
AUTOMATIC TEMPERATURE COMPENSATION
This feature automatically adjusts the output level setting based upon the changes in seasonal water
temperatures only. This unique feature conveniently compensates for warm (more purified needed) or
cold (less purified needed) water conditions.
*Remember that the output level is a time cycle based upon a 30-minute cycle. At 0% output, it is
generating 0 of 30 minutes. At 25%, it is generating 7.5/30 minutes. At 50%, it is generating 15/30
minutes. At 75% it is generating 22.5/30 minutes. And at 100% it is generating 30/30 minutes.
This is easier explained with the output level at 50% setting. At 70F, a 50% setting is truly 50%, thus
generating 15/30 minutes.
As the temperature increases to 80F, the 50% setting will still display as 50% but will continue to pulsate
(generate) 22.5/30 minutes due to the temperature compensation of 150%. 15 minutes x 150% = 22.5
minutes.
As the temperature increases to 90F or higher, the 50% setting will display 50% but will continue to
pulsate continually, 30/30 minutes. 15 minutes x 200% = 30 minutes.
As the temperature decreases to 65F, the unit will pulsate 11.25/30 minutes. 15 minutes x 75% = 11.25
minutes.
As the temperature decreases to 60F, the unit will pulsate 7.5/30 minutes. 15 minutes x 50% = 7.5
minutes.
As the temperature decreases to 50F or lower, the unit will pulsate 18 seconds/30 minutes, 30 x 1% =0.30
minute (18 seconds)
(**This is true for all output settings at 50F or lower)
1/17/03
SOFT TOUCH TECHNICAL SPECIFICATIONS
Temperature
50?F
55?F
60?F
65?F
70?F
75?F
80?F
85?F
90?F
SOFT REVERSAL
Chlorine Production Stops 30 seconds before
reversing polarity.
BOOST CYCLES
Solid Green light is 24 hour boost
Flashing Green light is 72 hour boost
(
Hold boost down for 8 seconds to get 72 hour boost)
Output adjustment
1% fixed setting
25% of 70F setting
50%
75%
100%
125%
150%
175%
200%
4