Autoplugin Key-V3 Panduan Pengguna - Halaman 6
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Unit Kontrol Autoplugin Key-V3. Autoplugin Key-V3 8 halaman.
3.
3.1.
Battery
Minimal battery
Monitoring
voltage that lets the
module start the
heater in pre-heat
mode
3.2.
Minimal battery
voltage that lets the
module keep
operating the heater
in pre-heat mode
6.
6.1. Indication of
Indication
heater startup
with
6.2. Indication of
direction
command reception
indicators in
from a remote
rearview
control
mirrors
6.3. Indication of
heater operation,
when starting
source is a remote
control
6.4. Indication of
heater operation,
when starting
source is the CIP
(direct start)
6.5. Indication of
heater operation,
when starting
source is other than
specified in 6.3,6.4
6.7. Flashing
frequency for 6.3-
6.4 Setup items
6
3.1.1 * Not adjusted
3.1.2 11.7V
3.1.3 11.8V
3.1.4 11.9V
3.1.5 12.0V
3.1.6 12.1V
3.1.7 12.2V
3.1.8 12.3V
3.1.9 12.4V
3.2.1 * Not adjusted
3.2.2 11.4V
3.2.3 11.5V
3.2.4 11.6V
3.2.5 11.7V
1
3.2.6 11.8V
3.2.7 11.9V
3.2.8 12.0V
6.1.1 *Off
6.1.2 Five flashes
6.2.1 *Off
6.2.2 Three flashes
6.3.1 *Off
6.3.2 On
6.4.1 *Off
6.4.2 On
6.5.1 *Off
6.5.2 On
6.7.1 One flash within 3 sec
6.7.2 One flash within 5 sec
6.7.3 * One flash within 10 sec
6.7.4 One flash within 15 sec