INSTRUCTIONS: Star Cod: DYN 09.1.19
Date: 14/12/2022 Revision: 19
reaches one of the floors, the current to the coil is cut, leaving the anti-creep system in the locked position.
–
The D-Box has a feature whereby, when the elevator reaches a floor, current continues through the
coil for a set time, usually 10 minutes, if the lift does not receive another call. After this time, the anti-
creep system locking device is activated. This correction is due to the VDI 4707 Part 1 (German lift energy
efficiency standard) which establishes a period of 5 minutes before stand-by.
Thus, the anti-creep system performs fewer on-off cycles, thereby increasing its useful life.
This is helpful in periods when there is heavy traffic, as it prevents the anti-creep system from repeatedly
locking and unlocking the overspeed governor.
It must be remembered that a UCM sensor will need to be installed if the anti-creep system works this
way
–
It is recommended to over-excite the coil with a voltage slightly above nominal for less than one second
to ensure the anti-creep system unlocks. Once it is unlocked and the lift begins to move, the supply
voltage should be reduced during the journey to lessen the coil heating.
Also, if the choice of keeping the coil excited while the lift is at a floor is taken, the voltage to the solenoid
can also be lowered. This saves energy and improves the energy efficiency of the lift.
Below is a table of recommended voltages
24V
48V
190V
(*) This is the voltage at the rectifier output, which can vary between the values shown.
–
To ensure proper operation of the device, it is advisable to design a circuit such that, if the inductive
sensor does not detect the anti-creep system unlocking, the controller will try more than once to supply
current to the coil (the Dynatech D-Box makes 7 attempts before the error message appears that no
reading for the inductive sensor is detected).
Thus, if there is any mechanical fault preventing the sensor from being read, the same attempts to solve
the problem will be made before an error message appears on the controller.
–
To prevent the car from stopping due to the loss of the inductive sensor signal while travelling, it makes
a reading only at the floors.
–
In the event of a cut in the electricity supply to the electric magnet coil when the car is moving, the
speed governor will lock and the safety gear subsequently engaged.
The installation of an autonomous power system is recommended to avoid undesired engagement in the
event of a cut in the mains electricity supply.
–
Open the pin to enable the speed governor to turn for manual rescue. If the pin is not released, the
governor will lock and the safety gear will engage during the rescue movement.
–
Open the pin to enable the speed governor to turn for automatic rescue. If the pin is not released, the
governor will lock and the safety gear will engage during the rescue movement.
–
Use in installations with re-levelling over 20 mm: in installations with re-levelling over 20 mm, certified
switching must be used to activate the electric magnet during the re-levelling process because if it re-
levels by more than 20 mm then the governor could lock and the safety gear engage. In this case, the
switching must discriminate between re-levelling and an uncontrolled movement.
–
Use in installations with door pre-opening: in installations with door pre-opening, certified switching
must be used to ensure the electric magnet remains activated during the pre-opening process because if
the electric magnet does not remain activated then the governor could lock and the safety gear engage.
In this case, the switching must discriminate between pre-opening and an uncontrolled movement.
4.4.3
THE PARKING SYSTEM AS REMOTE CONTROL
The parking can be used as remote control.
Operations are the opposite to those of the parking system, as it unlocks the governor when the lift is running under
normal conditions.
The purpose of the remote control system is to lock the governor when the lift is moving. This takes place during
Note: This manual displays partial information on the instructions for use and maintenance of this product. Please refer to the customer
area in Dynatech's website in order to consult the full manual; http://customers.dynatech-elevation.com/
Over-excitation
30 V
60 V
215-205 V (*)
Voltage during
travel
20 V
40 V
150 V
Voltage at floor
12V
30 V
104 V