CONNECTION OF THE HOB FOR HP6IFC-2
Mains
230V~ 50/60Hz
400V~ 50/60Hz
400V~ 50/60Hz
* calculated with the simultaneous factor following the standard EN 60 335-2-6/1990
Caution! Be careful that the cables are correctly engaged and tightened.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
Connection
Cable diameter
1 Phase + N
2 Phases + N
4 x 2.5 mm²
3 Phases + N
5 x 1.5 mm²
equipped with a faulty earth connection.
Cable
H 05 VV - F
3 x 4 mm²
H 05 RR - F
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
17
Protection calibre
40 A *
25 A *
16 A *