Gallagher TWR-1 Panduan Memulai Cepat - Halaman 5

Jelajahi secara online atau unduh pdf Panduan Memulai Cepat untuk Timbangan Gallagher TWR-1. Gallagher TWR-1 16 halaman. Weigh scale unit

Gallagher TWR-1 Panduan Memulai Cepat
Gallagher TWR-1 Weigh Scale Quick Start Guide
Installing the loadbars
If using loadbars, follow these steps:
1.
Select a weighing site that provides a solid, level and well drained surface.
2.
Ensure the loadbars and platform are well secured and clear of any
obstructions.
3.
Either bolt the loadbars to the concrete pad or locate them on studs set into
the concrete. It is important that the loadbars and platform sit flat without
any rocking or twisting to avoid weighing inaccuracies.
Note: It may be necessary to shim the loadbars or platform to ensure there
are no twisting pressures within the platform. Weights should be evenly
distributed over the top of the weigh bars.
4.
Connect the loadbar cables to the base of the TWR-1.
A beep will sound indicating a successful connection/ disconnection of the
loadbars.
WARNING – Do not weld the loadbars or any structure that they are
attached to. Loadbars contain sensitive electronic devices which will be
damaged by welding. Damage caused by welding will void warranty.
Position the TWR-1:
clear of the platform to ensure it does not interfere with the flow of
animals during the weighing cycle
within easy reach of the loadbar leads
within easy reach of the operator (for manual weighing)
5