7. Efficiency and emissions

Ecodesign 2015/1189
Kompakt 16
Manual ignition - the boiler should be used with a hot water tank of at least x* liters
Condensing boiler [no]
Fuel
Log wood, humidity ≤ 25 %
Characteristics when burning only the most suitable fuel
Useful heat release
Parameter
Symbol
At nominal heat
P n
output
At [30%/50%]
P p
rated heat
uotput, if
applicable
List of equivalent models
SP – solid particles, GOC – Gaseous organic compounds, CM – carbon monoxide
NOx - nitrogen oxides, ηs - Seasonal energy consumption efficiency for space heating
(Efficiency factor - 3%)
ηn - Seasonal energy consumption efficiency for space heating at maximum power
ηp - Seasonal energy consumption efficiency for space heating at 30% capacity
X - Chamber volume = 45 × Pr × (1 – 2.7/Pr) or 300 liters, whichever is greater, Pr is expressed in kilowatts
(kW)
Y - Chamber volume = 20 × Pr, Pr is expressed in kilowatts (kW)

8. Disposal of the boiler

The boiler must be disposed of in accordance with the requirements of the
country where it is disposed of.
17
Solid fuel cogeneration boiler [no]
Most suitable
Other
fuel
suitable
fuel
Yes
No
Value
Unit
13,0
kW
Non appli-
kW
cable.
Combined boiler [no]
η s [x%]:
Sezoninis patalpų šildymo išmetamųjų teršalų
kiekis
SP
GOC
[x]mg/m³
77±3
50±10
20±5
Heat utility
Parameter
Symbol
At nominal
η n
heat output
At
η p
[30%/50%]
rated heat
output, if
applicable
Kompakt 12, Kompakt 20
CM
NO x
589±10%
273±5%
Value
Unit
80,2
%
Non
%
applica-
ble.