5. Using the boiler

5.1 General information and sefety

Use the boiler safely and follow the basic safety and boiler
operation rules.
• Check the operation of the safety valve (max. 1.5 bar) and
open the shut-off valves between the heating boiler and the
heating system.
• Check the water pressure in the system.
• The heating system must be filled with water and bled.
• Do not use flammable liquids such as gasoline, paint thinners
etc. when starting solid fuel.
• Do not burn plastic, rubber and other air-polluting waste.
• The smoke extraction system must be reliably connected and
tight.
• Unmaintained chimney, insufficient draft can cause Carbon
monoxide poisoning.
• Carry out maintenance work on the boiler only after it has
cooled down.

5.2 Boiler fuel

Wood. The boiler will reach the power specified in the technical
parameter table if you burn wood with a moisture content
of no more than 20%. However, the Kompakt design allows
for the burning of wetter wood as well. The burning duration
depends on the amount of fuel charged, its quality, outdoor
and indoor temperature, the building's thermal resistance, the
working capacity of the boiler and the quality of compliance
with the recommendations of the user manual (connection and
adjustment of the boiler, heating water flow and temperature
maintenance).
Coal. Black coal mixture: medium and fine coal (50/50%).