SECTION C: LISN SETUP
C.1 • GENERAL
In setting-up the LISN-DUT-Receiver configuration to perform a test, please strictly adhere the
following sequence:
1. Connect the protective earth cable between the rear panel screw (indicated by the DIN
"ground" symbol ), and a suitable reference ground.
2. In case AFJ FFT 3010 EMI receiver or AFJ DDA55 Click Analyser are used, connect the LISN 15-
pin remote control connector on the receivers, to the corresponding 15-pin connector on the
LISN, via the appropriate logic signal cable supplied. In such case, totally automatic control of
the LISN can be achieved, via the instruments software interface. AFJ LISN LT32C/10 offers
current meter to read and measure Switching Operations and EUT absorption current, as per
CISPR 14-1 requirements (see Section E).
3. Connect the DUT power cord to the appropriate LISN power output.
4. Plug the LISN mains cord, into the LISN socket on the rear panel.
5. Plug the mains cord into an appropriate mains outlet (if applicable, an isolation transformer
will be interposed), different from the one used to power any other instrument.
6. Switch the LISN power-on, and power-on the test equipment.
7. Connect the AFJ FFT 3010 EMI receiver (or any other receiver / spectrum analyser) or AFJ
DDA55 Click Analyser N 50Ω coaxial input to the LISN BNC 50Ω coaxial output through
appropriate coaxial cable.
8. Important: the built-in pulse limiter and attenuator introduces 10dB attenuation during
measurement. Such attenuation shall be compensated to get proper results, so it is
recommended to insert a correction factor via the software of the measuring equipment used
together with the LISN, before starting any measuring session.
This correction factor shall be defined with reference to the Voltage Division Factor data of
the certificate of calibration of the LISN:
-
during conducted emission measurement with AFJ FFT 3010 EMI receiver (or any other
receiver / spectrum analyser), using the data from 9kHz to 30MHz for each phase (L1, L2,
L3 and N);
-
during click measurements with AFJ DDA55 Click Analyser, using the data of the four
analysis frequencies (150kHz, 500kHz, 1.4MHz and 30MHz) for each phase (L1, L2, L3 and
N).
C.2 • SELECTION OF THE CONDUCTOR UNDER TEST
The "CONDUCTOR UNDER TEST" (L1, L2, L3 and N), can be selected in manual operation of the LISN via
the relevant button on the LISN front panel.
In automatic operation, such selection is performed via or AFJ FFT 3010 EMI receiver either AFJ DDA555
Click Analyser control software.