4. Titanium, maintenance-free, active anode

4.1. Pros of the titanium anode

- reliable, durable protection
- low consumption of anodes
- no sludge on the anode
- not required regeneration
- guaranteed long-term operation of the tank
1. Titanium anode
2. Potentiostat (AC)
3. Grounded cord
NOTE ! Before installing the anode CORREX, remove existing protective magnesium anode.
1. Cable supplied bipolar, connecting the anode CORREX and potentiometer plug must not be lengthened.
2. A random change in polarity causes the acceleration of corrosion.
3. It is recommended to use the socket 230 V in a short distance from the tank.

4.2. Troubleshooting

LED CONTROL
ON - green colour
OFF
ON - red colour
© All rights reserved - Galmet Sp. z o.o. Sp. K.
4. Titanium, maintenance-free, active anode
CAUSE
- Anode CORREX working properly. Full
protection against corrosion.
- Lack of electricity.
- Lack of water in the tank.
- Cables between the electronic part and the
anode is connected incorrectly.
- Lack of contact between the ground (tank)
and the electrical part of the anode.
- The anode is contacted with the mass of
the tank.
Installation and Operating Manual / Warranty Card - SGW(S): Maxi / Maxi Plus / M
METHOD OF REMOVAL
-
- Check the voltage 230 V.
- Fill the tank with water.
- Put the cables at the anode.
- Check and clean the rust all connections.
- Properly isolate the anode from the tank.