Product Installation Guidelines
5. Check Shower for operation and leaks
Check the hose is securely connected. Turn on
water supply. Once installation is completed, the
unit must be tested for any leaks.
Notes:
1. To comply with backflow prevention
standards, the hand spray must hang at least
55mm above the floor providing an 'air-gap'. If
the hand piece lies on the floor, then an
appropriate backflow prevention device must
be installed.
2. Shown is a Clevakit typical installation
conforming to AS1428.1-2009.
For Tapware
6. Fit spindle assembly
−
Remove handle and flange from cartridge
assembly. Unscrew the ¼ turn ceramic head
part from the threaded sleeve assembly and
screw ceramic cartridge into the valve body by
hand, tighten using a 17mm spanner.
−
Refit threaded sleeve and spindle.
The ¼ turn ceramic head part MUST be fitted into
the wall body prior to refitting the threaded
sleeve and spindle. DO NOT tighten cartridge by
using the spindle or the threaded sleeve.
© Galvin Engineering Pty Ltd
Version 1, 1 June 2022, Page 4 of 6
Clevakit typical installation
Conforming to AS1428.1-2009
7. Fit wall flange
−
Ensure o-ring is fitted to the bottom of the
wall flange, and then hand-tighten the wall
flange onto the threaded sleeve.
th
Version 1, 25
May 2022, Page 4 of 6