HIK VISION DS-K4H258S Panduan Petunjuk Instalasi - Halaman 8

Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk Pengontrol HIK VISION DS-K4H258S. HIK VISION DS-K4H258S 9 halaman. Magnetic lock connect to access controller
Juga untuk HIK VISION DS-K4H258S: Panduan Pengguna (9 halaman)

HIK VISION DS-K4H258S Panduan Petunjuk Instalasi
DS-K4H250/450/258 series magnetic lock
Title:
connect to DS-K2600 series Access Controller
Product:
Access Control Device
Step 4:
Enter Access Control  Advanced Function  Access Control Parameters interface, set Door
Magnetic Sensor as Remian Open, and it should be consistent with the wiring of Door Magnetic
Singnal Output;
Step 5:
Enter Status Monitor  Door Status interface, open the door, check door status on iVMS-4200 Client
and the magnetic lock LED status;
Magnetic Lock
LED
status
Door Status
Alarm Event
NOTE:
Abnomal in Magnetic lock LED status part could be displaied in following scenario, open door
timeout, abnomally open door(by force), as well as not standard installation cuasing armature plate and
lock body contact are not fully fitted.