Galvin Specialised Ezy-Wash TF85-C Panduan Instalasi Produk - Halaman 2
Jelajahi secara online atau unduh pdf Panduan Instalasi Produk untuk Perlengkapan Dapur & Kamar Mandi Galvin Specialised Ezy-Wash TF85-C. Galvin Specialised Ezy-Wash TF85-C 5 halaman. Pre-rinse tapware
PRE-INSTALLATION
This installation instruction has two (2) sections:
1. New Installation
2. Retro-Fit
Select the appropriate section and follow the
instructions carefully.
Note: When a pot filler attachment is installed,
the overall height of the pre-rinse unit will
increase by 60mm.
INSTALLATION
INSTALLATION COMPLIANCE: Galvin Specialised products must be installed in accordance with these
installation instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements.
Water and/or electrical supply conditions must also comply to the applicable national and/or state standards.
Failing to comply with these provisions shall void the product warranty and may affect the performance of the
product.
New Installation: (The following instructions must be followed in all respects and read in conjunction with
installation and operation instructions supplied with new pre-rinse unit).
1. Fit pot filler and riser
Remove protective cap from upper riser spindle.
Fit the upper riser to the lower riser, ensure the sealing o-rings are inside the spindle.
Tighten with new supplied grub screw.
It is critical that the grub screw point locates accurately into hole recess of mating part. Failure
to do so may result in damage and/or failure of the unit.
Refer back to instructions supplied with new Galvin Specialised pre-rinse unit to complete installation.
Version 2, 4 August 2017, Page 2 of 5