Installation, Operation & Maintenance
PILOT WATER HEATER & BOILER LIMIT BREAKER
The device can be used to directly shut the pilot of a water heater in an alarm or power failure state using
a product from Field Controls. The BMS terminals may also be used to connect to a home alarm system.
Wiring example as shown.
REMOTE SHUT OFF
Your mini-merlin can be integrated with remote devices with an open /close circuit via the Remote Shut-
Off volt free switch terminal.
When using this input, only the mains utility output shall de-energize. If you are using the CO or NG relay
to shut down a boilers external limit circuit you will need to wire the input in series with the relay output.
Rev: 20 12-20
This terminal has a factory fitted link installed.
This terminal is normally closed and will alarm when energised open
- isolating the gas supply.
Mini-Merlin
10