AGS Mini Merlin CH4CO Panduan Pengguna - Halaman 12
Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Alat Ukur AGS Mini Merlin CH4CO. AGS Mini Merlin CH4CO 16 halaman. Dual gas detector, methane & carbon monoxide gas
Juga untuk AGS Mini Merlin CH4CO: Panduan Pemasangan & Pengoperasian (16 halaman)
MINI MERLIN CH4CO
USER GUIDE
Pilot Water Heater and Boiler Limit Breaker.
The device can be used to directly shut the pilot of a water heater using a product from Field
Controls. The BMS terminals may also be used to connect to a home alarm system.
Remote Shut Off.
Your device has a facility for remote devices to be connected.
The [Remote Shut Off] terminal is NC (Normally Closed) and will alarm when energised Open.
Remote devices cut off the gas supply
when activated.
To reset the device after a remote shut off has been activated – press the Touch Button.
Rev: 08 05-19
12