Main Combi 24 HE Panduan Pengguna - Halaman 3

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Ketel uap Main Combi 24 HE. Main Combi 24 HE 12 halaman. Wall mounted combination boiler gas fired central heating unit
Juga untuk Main Combi 24 HE: Panduan Pengguna dan Informasi Garansi Penting (12 halaman)

Main Combi 24 HE Panduan Pengguna
Supplied by HeatingSpares247.com
Reset
ON/OFF/Reset
Indicator Neons
Selector Switch
Reset
OFF Position
The boiler will not operate.
Burner On
Flame Failure
Power On
Indicator Neons
2
1
3
0
4
bar
© Baxi Heating UK Ltd 2011
Burner On
Flame Failure
Power On
Central Heating
Temperature Control
Reset
Central Heating & Hot Water
Both Heating & Hot Water will operate.
Burner On Indicator - The indicator will illuminate when the burner has fired and is heating
your central heating or domestic hot water.
Flame Failure Indicator - The indicator will illuminate when the burner has not fired.
Power On Indicator - The indicator will illuminate when there is power to the boiler.
Central Heating Temperature Control
Turn the knob clockwise to increase or anticlockwise to decrease the temperature.
Range 35 - 85° C.
Domestic Hot Water Temperature Control
Turn the knob clockwise to increase or anticlockwise to decrease the temperature.
Range 35 - 65° C.
Central Heating System Pressure - The normal operating water pressure is shown when the
needle is between 1 and 2.5 bar. If the pressure exceeds 3 bar the safety pressure valve will
operate and a fault is indicated. Contact your Installer.

1.0 Quick Reference Guide

Domestic Hot Water
Temperature Control
Reset
Domestic Hot Water
Hot Water will operate.
2
1
3
4
0
bar
System Pressure Gauge
Position of
Optional Timer
Reset
Hold for approx 5 seconds and release.
3