7) ML20800 TCAC2 Hardwiring Instructions
7.6) M35 Power/Remote Unlocking Harness
784
9VDC
+9 VDC
Power Supply
EGND
120 VAC L/N/G
Normally Open
momentary switch
(Remote unlock
- REX option)
NO
C
Black, 1
Red, 2
White, 3
Green, 4
Orange, 5
Blue, 6
Brown, 7
Yellow, 8
8 wires and pigtail harness
Installation:
®
1.
ElectroLynx System Wiring Instructions (refer to Fig. 1 and Fig. 3)
a. Look for the mating part on ASSA ABLOY doors and frames. Then plug in all
connectors as shown in Fig. 3 during product installation.
b. Hard wire 784 power supply as shown.
®
2.
Non-ElectroLynx System Wiring Instructions (refer to Fig. 1 and Fig. 3)
a. Cut the 8-pin connector off the Power/Remote Unlocking harness and hard wire
to non-ElectroLynx door harness. Remote power requires three conductors and
remote unlock requires two conductors.
b. Hard wire door harness to power transfer device.
c. Hard wire 784 power supply as shown.
Door
Outside
Escutcheon
-9 VDC
Power/Remote Unlocking
ElectroLynx Wiring System
QC8 Electric Hinge
with 8-pin connectors,
®
6 AA batteries MUST be removed from
controller if 784 Power supply is used.
Inside
Escutcheon
Fig. 3
®
®
ElectroLynx Door Harness
with 8 & 4-pin connectors.
Harness location is
dependent on door type.
18
ASSA ABLOY
Remote Power and
Ground Tab
REX Connector TB2
Motor
Connector
TB1
1 2 3 4 5 6 7 8
M35
Power/Remote
Unlocking
Harness
REX Input
Connect to
Device.
Only used in
combination
with the M861
Option.
It may be left
unconnected.
ElectroLynx® is a registered trademark of ASSA ABLOY Inc.
Copyright © 2014 Corbin Russwin, Inc. All rights reserved.
Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
®