Corbin Russwin ASSA ABLOY Access M806 Instruksi Pemrograman - Halaman 15
Jelajahi secara online atau unduh pdf Instruksi Pemrograman untuk Dengan kunci Corbin Russwin ASSA ABLOY Access M806. Corbin Russwin ASSA ABLOY Access M806 16 halaman.
Access 800
Series
™
Locks
Keypad Programming Instructions
7
M802 and M805 Programming
In a Prox Only M802 or RF Technology & Prox M805 configuration, all programming must be completed
using AccesswareTM Software. The Software includes a convenient Software User's Manual in .pdf
format to be used as a programming guide. After setting up your system using the software, Hotsync to
the PDA. Be sure to program a "Communications Enable" credential for future programming.
To program the lock for the first time or after memory is reset, the following steps are required.
1. Use AccesswareTM software to set up your system and Hotsync door information to PDA.
2. Remove Battery Cover from inside of lock.
3. On PDA - select "Access HH", then "Imp/Exp"
"Do NOT click OK at this point"
4. "Wake up" the M802 or M805 lock by presenting
any HID Prox Credential or by depressing an RF FOB
5. Within a couple seconds press and hold the controller CommEnable push button (white button
located in the battery compartment) for 2 seconds, then release the button.
6. On the PDA, click "OK"
If there was an error, check connections and repeat process starting at Step 3.
Note: The Credential will NOT actuate the lock for 45 seconds from the start of the downloading
process. After this time expires, the Credential will function as defined by its User Type.
Reprogramming
Note: Using the proximity card, FOB, tag or RF FOB programmed as a "CommEnable" User,
present the "CommEnable" credential to the lock to initiate communications after performing
Step 3 (above) without the need to press the CommEnable button.
For installation assistance contact Corbin Russwin
1-800-543-3658 • [email protected]
Copyright © 2018-2019 Corbin Russwin, Inc., an ASSA ABLOY Group
company. All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
PDA Response: "Please enter your
communications code at the door"
Lock Response: Audible beep
The PDA will begin transferring (0-100%) of
the door data to the lock.