Dea 124RR Petunjuk dan Peringatan - Halaman 3

Jelajahi secara online atau unduh pdf Petunjuk dan Peringatan untuk Panel Kontrol Dea 124RR. Dea 124RR 11 halaman. Control board 24v for gate automation operating

Dea 124RR Petunjuk dan Peringatan
Operating instructions and warnings
WARNING DEA System reminds all users that the selection, positioning and installation of all materials
and devices which make up the complete automation system, must comply with the European Directives
98/37/CE (Machinery Directive), 89/336/CE and subsequent amendments (electromagnetic compati-
bility), 73/23/CE and subsequent amendments (low voltage electrical equipment). In order to ensure a
suitable level of safety, besides complying with local regulations, it is advisable to comply also with the
above mentioned Directives in all non-European countries.

5 TECHNICAL DATA

Power supply ....................................................230 V a.c. +/- 10% 50Hz
Flashing light output .........................................24 V d.c. max 15W art. Lumy 24S
Auxiliary power supply output (+24VAUX) ..........24 V d.c. (max 200mA)
Safety devices power supply output (+24VSIC) ...24 V d.c. (max 200mA)
LC/SCA contact capacity LC/SCA ......................max 5A
Max motor capacity ..........................................70W max
Fuse F1 ............................................................T1A
Fuse F2 ............................................................T10A
Radio receiver frequency ...................................433,92 MHz rolling code / dipswitch coding
Max. number of transmitter controlled................100

6 OPERATING CONDITIONS

124RR control board is designed for the automation of DEA System gates operators in 24V a.c., and
therefore it is fit for overhead doors, sliding gates and barriers.
This control board is designed and tested for operation under "normal" conditions for both residential
and industrial use. The level of protection against dust and water and other data are illustrated in the
instructions booklet of each gate operator DEA System, equipped with the 124RR control board.
WARNING Using the product under unusual conditions not foreseen by the manufacturer may cause
dangerous situations; this is the reason why all the conditions prescribed in these instructions must be
followed.
WARNING Under no circumstance must the product be used in an explosive environment or surroun-
dings that may prove corrosive and damage parts of the product.
WARNING To ensure an appropriate level of electrical safety always keep the 230V cables (power sup-
ply) apart from low voltage cables (motors power supply, controls, aerial and auxiliary circuits power
supply), and fasten the latter with appropriate clamps near the terminal boards.
WARNING Any installation, maintenance or repair operation on the whole system must be carried out
exclusively by qualified personnel. All these operations must be performed only after disconnecting the
power supply, and operating in strict compliance with the electrical standards and regulations in force
in the nation of installation.
WARNING Install and wire the control board according to the instructions given in the instruction
booklet of each gate operator DEA System (such as hole drilling to allow for wires passage, use of wire
14
clamps, etc.)
Failure to comply with these instructions may jeopardize the level of electrical safety.
Connect to the power supply 230 V a.c. ± 10% 50 Hz through a multi pole switch or a different device
that can ensure multi pole disconnection from the power supply, with a contact opening of 3 mm. Use a
cable with a minimum section of 3 x 1,5 mm² (e.g. a H07RN-F type).
Make all connections to the terminal board and remember to short-circuit, whenever necessary, all
unused inputs. (See table 1 terminal board connection and Fig. 1 wiring diagram)
R

ASSEMBLY AND WIRING INSTRUCTIONS

250V (retarded)
250V (retarded)
A1
A2
A3
A5
A6