5. Replacing supply cord
If the replacement of the supply cord is necessary, this
has to be done by the manufacturer of this agent in order
to avoid a safety hazard.
6. Motor unit maintenance
The motor winding is an important part of this tool. Avoid
damaging and be careful to avoid contact with cleaning
oil or water.
After 50 hours of use, clean the motor by blowing into the
ventilation holes of the motor housing with dry air from an
air gun or other tool (Fig. 16).
Dust or particle accumulation in the motor can result in
damage.
7. Inspecting and maintaining the lower guard
Always make sure that the lower guard moves smoothly.
In the event of any malfunction, immediately repair the
lower guard.
For cleaning and maintenance, use an air gun or other
tool to blow clean the space between the lower guard
and gear cover as well as the rotation part of the lower
guard with dry air (Fig. 16).
Doing so is eff ective for the emission of chips or other
particles.
Accumulation of chips or other particles around the lower
guard may result in malfunction or damage.
WARNING
To prevent dust inhalation or eye irritation, wear
protective safety goggles and a dust mask when
using an air gun or other tool to clean the lower guard,
ventilation holes or other parts of the product.
Ensure smooth movement
of lower guard
Space between lower
guard and gear cover
Housing vent
CAUTION
In the operation and maintenance of power tools, the safety
regulations and standards prescribed in each country must
be observed.
NOTE
Due to HiKOKI's continuing program of research and
development, the specifi cations herein are subject to
change without prior notice.
Rotation part of the
lower guard
Air gun
Fig. 16