AgTerra SprayLogger E3 Panduan Instalasi & Mulai Cepat - Halaman 5
Jelajahi secara online atau unduh pdf Panduan Instalasi & Mulai Cepat untuk Peralatan Pertanian AgTerra SprayLogger E3. AgTerra SprayLogger E3 16 halaman.
4
Flow Sensor Installation
The VMZ induQ® flow sensor uses magnetic induction and works without any moving
parts. Because this type of flow sensor relies on electrical conductivity for operation,
it is important to install the meter in a manner that avoids electrical interference, air
bubbles in the flow stream (or running dry), and contamination from particles
settling out.
PLEASE READ THE OPERATING MANUAL INCLUDED WITH YOUR SENSOR.
This quick start guide only provides an overview.
Plumbing – VMZ Flow Sensor
To avoid false readings and contamination, mount the flow sensor in the lowest
possible position relative to the tank in a vertical position (flow going UP ↑).
If this is not possible, install in such a way that back washes or bubbles are
minimized. (See diagram).
RISK OF BUBBLES,
RUNNING DRY
BEST
RISK OF
CONTAMINATION
RISK OF
RUNNING DRY
RISK OF
CONTAMINATION