Dean Forge Croft Clearburn Junior Inset Panduan Petunjuk Pengoperasian - Halaman 8
Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian untuk Kompor Dean Forge Croft Clearburn Junior Inset. Dean Forge Croft Clearburn Junior Inset 19 halaman. Clearburn range
Table of distances from combustibles
Stove Type
Croft Clearburn Slimline
Croft Clearburn Small
Croft Clearburn Medium 1000mm
Croft Clearburn Large
Croft Clearburn Small
with Log store
It may be necessary to shield the beam or mantle piece from the heat. The single wall flue
from the top of the stove must be at least 3 times its diameter from combustible materials i.e.
150 (6") flue 450 (18") distance.
Be careful not to place furniture or other combustible material too close to the stove.
Register plates
Register plates, which have not got a continuous flue to the top, must be made of 1.5mm steel
treated to prevent corrosion (BS8303 part 3 9.5)
Register plates made of fireboard may only be used if a liner or flue runs from the top of the
stove to the top of the chimney without a break.
Minimum from back of
appliance to combustibles
850mm
850mm
1200mm
850mm
8
Minimum from side of
appliance to combustibles
700mm
700mm
700mm
800mm
700mm