Maiwe MIEN2204-2TS Panduan Pengguna - Halaman 14

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Beralih Maiwe MIEN2204-2TS. Maiwe MIEN2204-2TS 17 halaman. Unmanaged industrial ethernet switch

Maiwe MIEN2204-2TS Panduan Pengguna
MIEN2204 Series Unmanaged Industrial Ethernet Switch
The specifications, quantity, routing direction, and location of the cables to
be laid should meet the design requirements of the construction drawing. The
wiring length of each cable should be determined according to the actual
location.The user cables and power cables should be laid separately.
There must be no disconnection or joints in the middle of the laid cables
Cables should be laid out neatly in the aisle, and the bends should be
even, smooth and straight
The cable should be straight in the channel, and should not go out of the
channel and block other wire entry and exit holes. The cable should be bound
and fixed at the location of the cable exit from the channel or the cable bend
When the cables, power cords, and ground wires are laid in the same slot,
the cables, power cords and ground wires cannot be overlapped or mixed.
When the cable is too long, the cable must be neatly placed in the middle of the
cable rack, and cannot be pressed on other cables
When laying pigtails, prevent the optical cable from knotting and minimize
the turning points, and the turning radius should not be too small. The lashing
should be moderately tight and not too tight. When laying on the cable rack, it
should be placed separately from other cables
There should be corresponding marks at both ends of the cable, and the
content of the marks is concise and easy to maintain
Attention
When laying pigtails, prevent the optical cable from kinking and minimize
the turning point, and the turning radius should not be too small. If the turning
radius is too small, it will cause serious loss of the link optical signal. Affect the
quality of communication.
- 10 -