Adexa E50N52N24-SB Panduan Petunjuk Pengoperasian - Halaman 4

Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian untuk panggangan Adexa E50N52N24-SB. Adexa E50N52N24-SB 12 halaman. Outdoor gas bbq grill

ADEXA DIRECT LIMITED
Ground Floor, Unit 1, 214 Purley Way,
Croydon CR0 4XG United Kingdom
T:(+44)01483 931040 [email protected]
www.adexa.co.uk
Country of
Destination
BE,CH,CY,CZ,ES,
FR,GB,GR,IE,IT,LT,
LU,LV,PT,SK,SI
BE,CY,DK,EE,FI,HU,
LT,NL,NO,SE,SI,SK,
RO,HR,
TR,BG,LU,MT,JO
AT,CH,DE,SK
PL
Use Outdoors Only .
Read the instructions before using the appliance.
The gas cylinder should not be placed inside BBQ.
Warning : Accessible parts may be very hot. Keep young children away.
a)Choose the proper regulator according to appliance category and gas pressure in the table
above, for example, Use 30mbar regulator with appliance category I3B/P for propane gas.
The gas regulator should be in accordance with EN 16129 and comply with local code.
b)
Marking on injector, for example,0.86 indicates that the size of the injector is 0.86mm.

2. Mounting steps

Make sure your grill is assembled properly. Detailed assembly instructions are packed with
each grill giving specific assembly procedures for each model. Follow these instructions
carefully to ensure the correct and safe assembly of the grill.
Caution: Although we take every effort to ensure that the assembly process is as easy as
possible, it is inherent with fabricated steel parts that corners and edged can cause cuts if
improperly handled during assembly procedures. Be careful while handling any parts during
assembly. It is strongly recommended that you protect hands with a pair of work gloves。
3. Preparation
You will need LPG gas bottle and proper regulators under the gas pressure to operate this
gas grill. The regulators should be comply with EN12864 with current version and national
regulation.
See point 6 for farther instructions.

Energy saving tips:

Appliance Category
Butane(G30) 28-30 mbar 0.86mm 0.76mm
I3+(28-30/37)
Propane(G31) 37 mbar 0.86mm 0.76mm
I3B/P(30)
Butane/Propane 30 mbar 0.86mm 0.76mm
I3B/P(50)
Butane/Propane 50 mbar 0.75mm 0.66mm
I3B/P(37)
Butane/Propane 37 mbar 0.82mm 0.66mm
Product name: Outdoor gas Grill
Pin Number: 0063CN7292
Serial Number:
Burner
Gas and Supply
Pressure
Injector
Size Ø
3
Main
Side
E50N52N24-SB
Burner
Injector
Total Nominal Heat
Size Ø
Inputs (Hs)
14.5 kW 1054g/h
14.5 kW 1034g/h
14.5 kW 1054g/h
14.5 kW 1054g/h
14.2kW 1032g/h
0063-21