Insert the sealing ring (D) into the threaded sleeve (C)   
 
Thread the clamping nut (E) and the threaded sleeve (C) over the AC cable, and its order is 
shown in the figure below. 
 
According to polarities, insert the grounding conductor PE (green‐yellow) in the screw 
terminal with the earth sign on the socket screw; the neutral conductor N (blue) in the 
screw terminal N on the socket element; and phase L (brown or black) into the screw 
terminal L on the socket element then tighten the screw to make sure the wires are 
securely connected. 
 
After fasten the three wires with the terminal, combine every component together.