Turn cartridge spindle clockwise to
decrease the temperature. Turn
cartridge spindle anti-clockwise to
increase the temperature.
Servicing Intervals
Slide the
bracket onto the
riser rail, then
push the riser
extension onto
the riser rail.
Press & hold
knob on the
bracket to slide
up or down.
Secure the riser
Drill holes. Secure the
bracket and riser
bracket to the wall.
rail.
Symptom
Cause
No flow or
Partially closed isolation valve.
low flow rate
Instantaneous water heater cycles on and off
as flow rate or pressure is too low.
Head of water is below the minimum
distance required.
Hot or cold water being drawn off elsewhere
causing pressure changes or instantaneous
boiler temperature changes.
Airlock or partial blockage in the supply pipe
work.
Water
This is normal for a short time after using the
dripping
shower.
from shower
If water continues to drip, possibly due to the
cartridge
Shower does
Closed isolation valve.
not turn on
Mains water supply turned off.
At Bristan, we want to make things as easy as possible for our customers. That's why we offer solid guarantees
on all our products, effective from the date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your product.
Alternatively visit www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273 where our expert team of advisors
will be able to offer you any help and advice.
For full guarantee terms and conditions visit www.bristan.com/guarantees.
Tighten grub
screws at the
back.
Using a spirit level
To adjust the
to ensure the
height untighten
riser is positioned
and move the
correctly, use
arm to the
the assembled
desired height
riser to mark the
then tighten
desired position
again to secure
of the bracket.
in place.
Attach the fixed
head.
To adjust height
of head twist
the knob and
slide the riser to
desired height.
Remedy
Open isolation valve.
Increase water flow rate or pressure through system.
2 meters minimum required.
Do not use other water outlets when using the shower.
Flush through pipe work to ensure removal of debris and
any airlocks.
This is caused by residual water tension, the build up of
water in the shower.
Remove cartridge and clean, refer to 'Maintenance' section
before starting any maintenance.
Open isolation valve.
Turn on mains water supply.