accuracy for long-term installations. It outputs SDI-12, and is com-
patible with Decagon's Em50, Em50R, Em50G, and other loggers
like those from Campbell Scientific.
1.6
Specifications
Wind Speed Range: 0 to 30 m/s
Wind Speed Resolution: 0.01 m/s
Wind Speed Accuracy: 0.30 m/s or < 3%, whichever is larger
Wind Direction Range: 0 to 359 degrees
Wind Direction Resolution: 1 degree
Wind Direction Accuracy:
Operating Temperature Range: 40 to 50 C
Excitation Voltage: 3.6 to 15 VDC
Current: 0.03 ma quiescent, 0.5 ma; sampling, < 0.05 ma typical
Communication: SDI-12
Diameter: 100 mm
Height (wind sensor): 75 mm
Height (total w/ mount): 155 mm
Maximum sampling speed
1
Output
: average speed, gust speed, direction, or vector
Connector types: 3.5 mm (stereo) plug or stripped & tinned lead
wires (Pigtail)
Cable Length: Standard is 5 m, though we have custom cable
lengths available upon request
1
If sampling rate is greater than 0.1 Hz, the anemometer reports the speed
and direction at the time of sampling. If sampled less frequently, the anemome-
ter samples every 10 seconds, averages the vector components of the wind, and
keeps the maximum gust. When the logger samples, the anemometer reports the
average wind speed, direction, and the maximum gust speed.
3 degrees
1
: 1 Hz
3
1 INTRODUCTION