Bristan IRBS4-CP Petunjuk Instalasi dan Panduan Pengguna - Halaman 10

Jelajahi secara online atau unduh pdf Petunjuk Instalasi dan Panduan Pengguna untuk Produk Pipa Bristan IRBS4-CP. Bristan IRBS4-CP 20 halaman. Infrared temperature control automatic basin spout
Juga untuk Bristan IRBS4-CP: Petunjuk Instalasi dan Panduan Pengguna (16 halaman)

Bristan IRBS4-CP Petunjuk Instalasi dan Panduan Pengguna
Installation -
Connect Power Supply Cable
Before starting any electrical
work ensure the power supply is
isolated.
Wire the electrical power cable into a
switched fused spur off the ring main.
The blue wire should be wired to the
neutral connection and the brown
wire should be connected to the live
connection.
Note: For full electrical requirements
see 'Electrical Connections' in
'Installation Requirements' section on
page 7.
Important: This product must be
permanently connected to the fixed
wiring of the mains supply using the
factory supplied power cable.
Power/ Sensor Cable Connection
Connect the transformer cable to the
sensor and battery box connectors.
Attach The Wall Bracket
Attach the wall bracket to the wall by
using screws and wall plugs provided.
Place the battery box into the battery
housing bracket and attach to the
wall bracket.
Setting Up The Sensor
Once the tap has been installed,
disconnect the sensor connector from
the transformer cable for 30 seconds,
Reconnect and put the hand at the
required position in front of the
sensor until the light stops flashing.
10
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.

Electrical Connections

Tranformer cable
Battery Housing
Bracket
Sensor connector
Battery box connector
Battery Box
Wall Bracket