Symptom
Flow of water
too high.
Spout runs
randomly
without a user
present.
Sensor light not
working.
Short cycles of
batteries.
Infrared sensor
flickering.
16
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
cont.
Cause
Inlet water supply pressure too
high.
Object in the sensing range.
Sensor light faulty.
Circuit board faulty or has been
allowed to get wet.
Batteries are exhausted.
Incorrect batteries fitted.
Batteries running low.
Remedy
Adjust inlet water pressure
accordingly. Refer to
'Specifications' section on page 6.
Ensure the sensing range is
clear.
Contact Bristan Customer
Services on 0844 701 6273.
Contact Bristan Customer
Services on 0844 701 6273.
Replace batteries.
Replace batteries. Ensure
batteries are 1.5V AA (LR6)
Alkaline batteries (preferably
=>2000mAh) for good battery life.
Replace batteries. Ensure
batteries are 1.5V AA (LR6)
Alkaline batteries (preferably
=>2000mAh) for good battery life.