Adey MagnaClean Micro2 Instalasi dan Servis - Halaman 6
Jelajahi secara online atau unduh pdf Instalasi dan Servis untuk Sistem Penyaringan Air Adey MagnaClean Micro2. Adey MagnaClean Micro2 8 halaman.
4 10
O ring
1
The lid seal should be cleaned
and checked for wear when
servicing MagnaClean. It is
Best Practice to replace the
lid seal at each service.
Only use Silicon grease or
water to lubricate O ring.
Do not use flux or EP grease.
4 13
2
1 - Turn valves on.
2 - Vent.
3 - Wipe filter dry.
4 11
Hand
tighten.
3
1
4 12
Tighten by a ¼ turn.
Important - Do NOT
overtighten.