Adey MagnaClean Professional3 Sense Instalasi dan Servis - Halaman 14
Jelajahi secara online atau unduh pdf Instalasi dan Servis untuk Sistem Penyaringan Air Adey MagnaClean Professional3 Sense. Adey MagnaClean Professional3 Sense 16 halaman. Wi-fi enabled magnetic filter
Juga untuk Adey MagnaClean Professional3 Sense: Instalasi dan Servis (20 halaman)
What do I do if I can't get the product to connect?
If the product will not connect after 3 attempts, it is recommended to perform a factory reset.
Access this via the ADEY ProClub App menu and follow the on-screen instructions.
It is also good practice to check the signal strength of the homeowner's Wi-Fi router from the intended
product position before installation. This can be easily checked by asking the homeowner to check the
signal strength on their phone from the intended product installation position.
How do I manage my filter stock within the App?
Upon set up of a MagnaClean Professional3 Sense you can manually choose how the filter will appear
in your job dashboard. We recommend using the customer's name as it will make it easy to manage
each filter within your job records.
Does the App store the homeowner's system details for future reference?
The homeowner's system details are stored within the 'Job records' section of the App and can be
referenced at any time prior to attending an onsite visit.
What are the Wi-Fi connectivity limitations?
The MagnaClean Professional3 Sense should be installed so that it can communicate wirelessly with
the router (up to a maximum distance of 30m). The home's construction and arrangement may affect
the communication range. Metal objects such as refrigerators and freezers, hot water cylinders, foil
lined plaster board walls, radiators and even thick brick walls, may reduce the Wi-Fi operational range
of the filter.
It is important to check the Wi-Fi strength at the proposed location of the filter before installation.
Technical specification
Operating Parameters:
Internal water operating temperature: 3°C to 95°C
Internal operating water pressure: Up to 6 bar
Recommended ambient room temperature: 3°C to 35°C
Maximum flow rate: 50L/min
Flow direction: Bi-directional
Fluid capacity: 0.55 litres
Inlet: 22mm compression at valve
Outlet: 22mm compression at valve
Electronic sub-assembly:
Enclosure rated to IP52 specification
Battery powered: 2x AA alkaline batteries