Specifications
Specifications
Working Pressures
Min: 0.01 MPa
Max: 0.5 MPa
(0.1 bar)
(5.0 bar)
3.0
2.0
4.0
1.0
1.0
5.0
0.
0.
Pressure
BAR
Maximum Static Pressure:
1.0 MPa (10.0 bar)
Installation
IMPORTANT: Please ensure both supply
pipes are flushed before connecting the
mixing valve to prevent plumbing/pipe
debris from entering the mixing valve.
1. Choose the configuration of the
elbows as per the diagram below.
Choose whether to have a top or
bottom outlet by using the blanking
cap and o-ring.
2. Plumb the pipes to the desired
location for the mixing valve.
3. Remove the backplate and mark the
position of the fixing holes.
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Cold Water Supply
3.0
2.0
4.0
5.0
Min: 5°C Max: 20°C
Pressure
BAR
IMPORTANT
Inlet Water Temperature
Hot Water Supply
20°C
5°C
65°C Recommended
The inlet hot water must
be at least 10°C above the
required blend temperature.
4. Drill and use the screws and plugs
provided to secure the backplate to
the wall.
5. Connect the valve to the pipework,
using filters to prevent debris
entering the valve (not supplied).
We recommend using a high
tightening torque (45-50Nm) on all
22mm compression fittings to
secure the valve.
Remember: Ensure the valve is fitted
with the hot inlet on the left, cold
on the right when viewed from the
front.
6. Locate the valve body on to the
backplate and secure with the
grub screw.
80°C
TMV Designation
65°C
HP-T44 & LP-T44
Maximum Pressure
Inlet & Outlet
Connection
22mm
Differential:
10:1
3