Positioning
The stove is furnished with an electrical cable
to connect to a 230V 50Hz socket, preferably
with a thermal-magnetic switch. Variations in
tension of more than 10% can compromise
the stove (if not already present, an adequate
differential switch should be provided).
The electrical system must comply with the
norms; verify in particular the efficiency of
the ground circuit. The electrical feed cable
must be of a diameter adequate to the power
of the device.
The stove must be completely level. Verify the
weight bearing capacity of the flooring.
The placement of the stove within the living
environment is determined so that the
environment is heated in a uniform manner.
Before deciding where to place the stove,
keep in mind that:
• The air used for combustion must not come
from a garage or a space without ventilation
or air exchange, but from a free space or the
outside;
• The stove should not be installed in a
bedroom;
• Rather it is preferable to install the stove in a
large, central room of the house to insure the
maximum heat circulation;
• A grounded electrical connection is obligatory
(if the cable issued with the stove is not long
enough to reach the closet socket, use an
extension cable along the floor).
Fig. 6: minimum distance of objects
5/7 cm
40 cm
20 cm
40 cm
80 cm
Fire Safety Distance
The stove must be installed respecting the
following safety conditions:
• Minimum distance from the sides and the
back must be 40 cm from moderately
inflammable material;
• Easily inflammable material must not be place
closer than 80 cm in front of the stove;
• If the stove is installed on an inflammable
pavement the stove must be placed on a
slab of material that insulates it from the heat
that is wider at the sides by 20 cm and in the
front by 40 cm;
• Do not place objects in inflammable material
or any material that can compromise the
operation of the stove on the stove or within
the safety distance;
• In addition, it is advisable to keep all
elements of combustible or inflammable
material such as beams, wooden furniture,
drapes, inflammable liquids, etc. outside the
radiance area of the stove, and in any case
at least 1 m from the heating block (Fig. 6);
• In case of connection to wooden walls or
other inflammable material, it is necessary
to insulate the smoke discharge tube with
ceramic fibre or another material with the
same characteristics.
40 cm
20 cm