Dimensions
External air intake:
The stove must be equipped with the air neces
sary to guarantee the regular functioning of the
combustion and an environmental well-being.
• Be sure that the room where the stove is
installed has sufficient ventilation and, if
necessary, install an air intake duct with a
minimum recommended diameter of 50 mm to
bring in air from the outside.
• The external air intake must be connected to
the stove and positioned so that it is not
obstructed. It must be protected with a
permanent non-closable grill or other suitable
protection provided that the minimum diameter
is not reduced.
Dimensions of CentroPelet Z8
495
- All dimensions are in mm
- tolerance 10 mm
+
-
• The presence in the local adjacent to where the
stove is installed, of other devices in use or of
suction devices that cause a contrary draught
effect must not create a lower air pressure in the
locale than in the outside environment.
• In the adjacent locale the permanent openings
must respond to the requisites which are listed in
the points above.
Ć 48/50
490
Ć 80
220
330