Advanced Set Up
Advanced Setup Guide – Level 2 Security to Change
#
Limit (Default)
(0)
0-4 (0)
(1)
0-4 (0)
(2)
+/- 100F or 50C (20F)
(3)
999 Seconds (60 Sec)
(4)
932F or 500C (932F)
(5)
+/- 100F or 50C (20F)
(6)
600F or 315C (220F)
(7)
-1 to 27 (0)
(8)
-1 to 2 (0)
(9)
0 or 1 (0)
(10)
0 or 1 (0)
(11)
0 or 1 (0)
(12)
0 or 1 (0)
(13)
0-99 (0)
(14)
0-3 (0)
(15)
- - -
(16)
- - -
(17)
000 - 999 (None)
(18)
000 - 999 (None)
(19)
0-999 (Custom)
(20)
0 (0)
(21)
0-6 (0)
(22)
- - -
(23)
- - -
(24)
- - -
(25)
- - -
(26)
- - -
(27)
- - -
(28)
000 - 999 (Level 2)
The GLC 2K is shipped to the customer so that No set up work is required for basic operation. Set points in Automatic and
Manual may be entered and the zone will be controlled by turning on the zone's power switch. Many customers require advanced
features to satisfy their operation. This page will describe the basics of "Advanced Set Up". Please note that security level codes are
not standard. To place security on the GLC 2K you must activate security by selecting your own personalized security codes.
To Access Advanced Set Up, Press both Select buttons at the same time,
hold and release. Selection LED's go dark when in Setup Mode.
The View Area will display the Set Up Number.
The Change Area will display the Current Value.
To Scroll Up – Press the View Area Select Key
To Scroll Down – Press the Change Area Select Key
To Make a change – Press the + or - Keys.
To Confirm the Change – Press Enter.
To Set up the Controller please reference
the Advanced Set Up Guide.
Explanation
Restore Mold Set Up - Access Setup, 0-View Area, Select Mold Set Up 1-4 - Change Area, Enter
Save Mold Set Up - Access Setup, 1-View Area, Save As 1-4 - Change Area, Enter
Boost Set Point, Timed Automatic Temporary Set Point Change for the selected zones
Boost Time Set Point - The amount of time the selected zone or zones will change temporarily
Automatic Set Point Limit - The Maximum Set Point the operator can enter in Automatic
Temperature Deviation Alarm Set Point - Set Point activates temperature alarm at that # +/-
Standby Set Point - When Standby is Selected it will control to this number in Automatic
Control Algorithm Adjustment, 0=Auto Select (1=Tip Tuning; 2=Man. Tuning). Manual Selections:
-1=Faster Control (Tips), 10=Tip; 11-17=Tip with increasing lag, 20=Manifold, 21-27=Manifold with increasing lag
T/C Pinch Detection Time, 0 Normal = 100% Output, 20F in 5 Min. -1 Faster (Tips), 1-2 Slower (Manifolds)
Slaved Power Up - Heat all zones to Set Point within 20F of one another, 0 - "Off " 1 – "On"
Degree F or C Selectable, 0 = Degree F, 1= Degree C
Type J or K Thermocouple Input, 0 = Type J, 1 = Type K
Host Computer Protocol, 0 = Gammaflux Protocol (Mold Doctor, etc.), 1 = Euromap 17 Protocol
Network Port Device Number – The address of the controller on the Euromap 17 Network.
Host Baud Rate – Communication Speed; 0=9600, 1=4800, 2=2400, 3=1200
Reserved for Future Use
Reserved for Future Use
Security Code Level 1 – You Must be in Level 2 to Change, Refresh procedure available, call the factory
Security Code Level 2 – You Must be in Level 2 to Change, Refresh procedure available, call the factory
Zone Finder – Activate Press 999, Hundreds show T/C inputs 1-3 Tiers, Tens/Ones show # of Output Modules
LED Test - Enter 0, Press Enter. Turns "On" all LED's for Troubleshooting
Error Status, Select Zone, View Error. 0=No Error, 1=No Communication, 2=Zone Not Allocated,
3=Output Controller Not Receiving Temperatures, 4=No Sync/Lost Phase,
5=Communication Error/Checksum, 6=Communication Error/Exceeded Limit
Output Controller Software Version Number (Display Only), Select Zone, Version Displayed
Output Controller Software Revision Number (Display Only), Select Zone, Revision Displayed
Temperature Module Software Version Number (Display Only), Select Zone, Version Displayed
Temperature Module Software Revision Number (Display Only), Select Zone, Revision Displayed
Operators Panel Software Version Number (Display Only), Select Zone, Version Displayed
Operators Panel Software Revision Number (Display Only), Select Zone, Revision Displayed
Security Level Indicated, 0=Lockout, 1=Operator, 2=Supervisor. 0 - Enter, Drops one Level.
Elevate One Security Level at a Time with your Customized Code. Then Press Enter.
Access/Exit Advanced Setup
Instructions