Centurion D2 Turbo Panduan Pemasangan Saku - Halaman 2
Jelajahi secara online atau unduh pdf Panduan Pemasangan Saku untuk Pembuka Pintu Garasi Centurion D2 Turbo. Centurion D2 Turbo 2 halaman. Domestic sliding gate operator
theft-resistant nut and padlock kit
Juga untuk Centurion D2 Turbo: Panduan Instalasi (9 halaman), Panduan Pemasangan Saku (13 halaman), Panduan Instalasi (2 halaman)
9. Electrical setup
9.1. Always check that the circuit breaker in the
electrical panel is in the OFF position, and that
all high voltage circuits (more than 42.4V) are
completely isolated from the mains supply
before doing any work.
9.2. Ensure that all low voltage systems (less than 42.4V) are
suitably protected from damage, by disconnecting all
sources of power such as chargers and batteries before
doing any work.
9.3. All electrical work must be carried out according to the
requirements of all applicable local electrical codes. (It is
recommended that a licensed electrical contractor perform
such work.)
Connect all wiring
Wire the controller to the required input and output devices as per the
wiring diagrams on the right hand side.
10. Setting up the system
Refer to the illustration of the D2 Turbo controller, which shows the
position of the Function and Setting Dials, the status LED, and the
select/toggle
Pushbutton.
All programming is done by means of two rotary Dials, a Pushbutton,
and the bi-colour (red and green) status LED.
The rotary Function Dial selects the required function you wish to
set. This is selected first.
Secondly, the rotary Setting Dial dials in the actual setting for the
function selected.
10A. Using the Pushbutton and status LEDs
To select a particular setting, press the
pushbutton
The status LED indicates the status of the setting
A green status LED indicates that particular setting is selected
A red status LED indicates it is off or not selected
If the setting is a single fixed value, e.g. 15 second
autoclose time, then the pushbutton acts as a select.
If the setting has an option such as On/Off, or Hi/Low
then the
pushbutton will act as a toggle.
If the status LED is green, then the first option is selected
If the status LED is red, then the second option is selected
10B. Using the Function Dial
The Function Dial has six different settings that may be selected:
RUN:
Fully anti-clockwise. The unit must be left in this
position for "Normal run" operation
A - LIMITS:
Sets up the gate open and closed positions
automatically.
B - REMOTES:
Allows for NOVA remotes to be added or deleted
C - AUTOCLOSE: Allows for different Autoclose times to be set
D - MODE:
Allows for different modes of operation to be set
E - PROFILE:
Allows for specific gate profiles to be toggled
On/Off or Hi/Low
10C. Using the Setting Dial
The Setting Dial has six different positions, which allow the function
required, to be selected.
Function dial
Setting dial (Ring position-Dial position)
A-1 Automatic; Start with gate closed
A - LIMITS
B-1 Learn a transmitter button to Trg
B-2 Learn a transmitter button to Ped
B - REMOTES
B-3 Learn a transmitter button to Lck
B-4 Delete a transmitter
B-5 Delete all transmitters
C-1 Autoclose off
C-2 Autoclose after 5 seconds
C-3 Autoclose after 10 seconds
C - AUTOCLOSE
C-4 Autoclose after 15 seconds
C-5 Autoclose after 30 seconds
C-6 Autoclose after 45 seconds
D-1 Standard Mode
D-2 Open Only Mode
D-3 Reversing Mode
D - MODE
D-4 PIRAC Mode
On
Off
D-5 Pre-Flash Mode A
On
Off
D-6 Pre-Flash Mode B
On
Off
E-1 Positive Close Mode
E-2 Speed
Hi
Low
E-3 Sensitivity
Hi
Low
E-4 Backup to Backup Memory Module
E - PROFILE
E-5 Restore from Backup Memory Module
Use toggle pushbutton to select preference.
For D - MODE, green status LED=On; red status LED=Off
For E - PROFILE, green status LED=Hi; red status LED=Low
PFA: The Pillar light relay will activate for two seconds before gate movement
occurs, as well as during gate movement. This means gate movement will be
delayed for a period of two seconds after a trigger has been received.
PFB: The pillar light relay will only activate during gate movement
Hi Speed: Gate will operate at its maximum speed – typically 24 metres per minute
Low Speed: Gate will operate at 16 metres per minute
Backup Memory Module (CP108) connected via DOSS connector socket
E
110 - 220V
N
Mains in
L
Waterproof isolator
enclosure within
two metres of motor
Pillar Light/
optional
Courtesy Light
OR
IMPROVED
LIGHTNING
PROTECTION
If Backup to Backup Memory Module or Restore from
Backup Memory Module are required, remove DOSS
connector and fit CP108 (Backup Memory Module)
See 'Using the Setting Dial', section E - Profile, E-4 and E-5.
Any controllers not marked with 'BACKUP' and 'RESTORE' do
not support this function
E-4 and E-5 text is not screened on the BETA versions
SETUP:
SETUP:
Step 1: Select FUNCTION
E
Step 2: Select SETTING
Step 3: Press
N
Step 4: When finished
L
select RUN
LIGHT
FUNCTION
Status LED
30A
ENCODER
ORIGIN
A B C D E
SETTING
POLOphone
POLOphone
optional
entry panel
handset status LED
Connection type: Normally open
Connection type: Normally closed
1
2
-
NO
COM
For enhanced security, connect the
entry panel to a POLOswitch at the
operator
Holiday Lockout
optional
keyswich
Connection type: Normally closed; latching contact
CP106
i5 Infrared safety
optional
Relay Card
beam (opening)
Connection type: Normally closed
To alarm
panel, etc
Rx
Relay card
IRB Receiver
CP106
Aux 12V
Safe Com
Com
Safe OPN
Safe CLS
LCK/STP
TRG
PED
Aux I/O
Com
IRB Receiver
LED
Rx
optional
12V+
12V-
TRG
PED
NC
COM
optional, but
recommended
Tx
IRB Tx - Open
IRB Tx - Close
Tx
1
2
3
4
5
6
7
8
9