Airflow iCON Panduan Instalasi dan Pengoperasian - Halaman 4
Jelajahi secara online atau unduh pdf Panduan Instalasi dan Pengoperasian untuk Kipas angin Airflow iCON. Airflow iCON 9 halaman. Domestic dc fans
Front Cover Removal
UNDO THE RETAINING
SCREW AT THE BOTTOM
EDGE OF COVER USING A
SCREWDRIVER.
The 15S requires a 110mm diameter hole through the wall, lined with a 100mm id (internal
diameter) duct.
The 30S requires a 110mm diameter hole through the wall, counter bored 160mm diameter
to a depth of 75mm. The 110mm hole should be lined with a 100mm id duct.
Surface Mounting on the Wall
When surface mounting the 30S, the supplied mounting skirt should be used. The 30S
requires a 110mm diameter hole through the wall lined with a 100mm id duct.
Recessing Fans in the Ceiling
POSSIBLE CABLE
ROUTING
CEILING
When recessing fans in the ceiling, a plywood support (min 18mm thick) should be mounted
between the ceiling joists. Fans should not be fitted to unsupported plaster board.
The front cover has a bayonet type
fitting. To remove, undo the retaining
screw at the bottom edge of the cover
using a screwdriver, then rotate the
cover a few degrees anticlockwise and
remove. To refit, reverse the above
procedure.
Page 4 of 8
DUCT
JOIST
PLYWOOD