Electrical requirements
If codes permit and a separate ground wire is
used, it is recommended
that a qualified
electrician determine that the ground path is
adequate.
Do Not ground to a gas pipe.
Check with a qualified electrician if you are
not sure the cooktop is properly grounded.
Do Not have a fuse in the neutral or ground
circuit.
IMPORTANT:
Save Installation Instructions for electrical
inspector's use.
A=
A three-wire or four-wire, single phase,
240-volt, 60-Hz, AC-only electrical supply is
required on a separate, 40-ampere circuit, (Note:
The KECC051 series requires a 20-ampere
circuit), fused on both sides of the line. A time-
delay fuse or circuit breaker is recommended.
The fuse size must not exceed the circuit rating
of the appliance specified on the model/serial
rating plate located on the bottom of the cooktop.
B
m THE COOKTOP MUST BE
CONNECTED WITH COPPER WIRE ONLY.
C=
Wire sizes and connections must conform
to the requirements of the National Electrical
Code ANSI/NFPA 70 - latest edition **, or CSA
Standards C22.1-94, Canadian Electrical Code,
Part 1 and C22.2 No. 0-M91 - latest edition ***
and all local codes and ordinances.
D
m The cooktop should be connected directly
to the fused disconnect or circuit breaker box
through flexible, armored or non-metallic
sheathed, copper cable. The flexible, armored
cable extending from the fuse box or circuit
breaker box should be connected directly to the
junction box.
E=
Locate the junction box to allow as much
slack as possible between the junction box and
the cooktop so that the cooktop can be moved if
servicing is ever necessary. Do Not cut the
conduit.
Fm
A U.L.- or C.S.A.-listed conduit connector
must be provided at each end of the power
supply cable (at the cooktop and at the junction
box).
Copies of the standards listed may be obtained from:
** National Fire Protection Association
Batterymarch
Park
Quincy, Massachusetts
02269
*** Canadian
Standard Association
178 Rexdale Boulevard
Etobicoke (Toronto),
Ontario
M9W 1R3
Electrical connection
For model KECC051
series only:
Electrical Shock Hazard
Turn power supply off before connecting
wires.
Use 12-gauge solid copper wire.
Electrically ground cooktop.
Failure to follow these instructions can
result in death, fire, or electrical shock.
This cooktop must be connected to a
grounded, metallic permanent wiring system or
a ground connector
should be connected
to the
ground terminal or wire lead on the cooktop.
This cooktop is manufactured with a frame
connected, green or bare ground wire. Connect
the cooktop cable to the junction box through the
U.L.- or C.S.A.-listed conduit connector.
Complete electrical connection according to local
codes and ordinances.
Panel B
For all models except KECC051
series:
Electrical
Shock Hazard
Turn power supply off before connecting
wires.
Use 8-gauge solid copper wire.
Electrically ground cooktop.
Failure to follow these instructions
can
result in death, fire, or electrical shock.
This cooktop must be connected to a
grounded, metallic permanent wiring
system
or a ground connector should be connected
to the ground terminal or wire lead on the
cooktop.
This cooktop is manufactured with a frame
connected, green or bare ground wire. Connect
the cooktop cable to the junction box through the
U.L.- or C.S.A.-listed conduit connector.
Complete electrical connection according to local
codes and ordinances.
For all cooktop
models with three-
wire cable from the cooktop:
A=
Where local codes Do Not permit
connecting the frame-ground
conductor to
the neutral (white) junction box wire. (Used
for Canadian installations):
I
4-wire cable from power supply
red wires
"unction
box
white wire
connector
bare or green
ground wires
3-wire
black wires
U.L.- or C.S.A,- listed
conduit connector
p
Ungrounded
neutral
Figure
1
1. Disconnect
power supply.
2. Connect the flexible, armored cable from the
cooktop to the junction box using a U.L.- or
C.S.A.-listed conduit connector. Tighten screws
on conduit connector.
3. Connect the two black wires together; then
connect the two red wires together using twist-
on connector. (See Figure 1.)
4. Connect the green or bare ground wire from
the cooktop cable to the grounded wire in the
junction box or other grounded connector
using twist-on connector.
5. Put a twist-on connector on end of white wire.
Do Not connect
bare ground wire to neutral
(white) wire in junction
box.
B=
Where local codes permit connecting
the frame-ground
conductor to the neutral
(white) junction box wire. (Not used for
Canadian installations):
3-wire cable from power supply
red wire_
r__l_
' :nw_.:it_n b°x
nectors
whitew, II
-2/d
_
black wires
bare ground wire r
3-wirecablefromcooktop
_
conduitconn
/
_
U'L"°rC'S'Aec_iled
Grounded
neutral
Figure 2
1. Follow steps 1 and 2 from "A" above.
2. Connect the bare cooktop wire with the white
wire; the two red wires together; and the two
black wires together using twist-on connectors.
(See Figure 2.)
For all cooktop
models with four-wire
cable from the cooktop. (These
cooktops
are manufactured
with white
(neutral) power supply wire and a
cabinet-connected
bare ground wire
factory-crimped
together.):
A=
Where local codes Do Not permit
connecting the frame-ground
conductor to
the neutral (white) junction box wire: (Used
for Canadian installations):
4-wire cable from power supply
red wires
"unction
box
white wires
connector
bare or green
wires
U.L,- or C.S,A.- listed
conduit
connector
4-wire cable from cooktop
Ungrounded
neutral
Figure
3
1. Disconnect
power supply.
2. Connect the flexible, armored cable from the
cooktop to the junction box using a U.L- or
C.S.A.-listed conduit connector. Tighten screws
on conduit connector.
3. Connect the two black wires together; then
connect the two red wires together using twist-
on connectors. (See Figure 3.)
4. Separate the factory-crimped
bare and white
cooktop cable wires.
5. Connect the two white wires together using
twist-on connectors.
6. Connect the bare ground wire from the
cooktop cable to the grounded wire in the
junction box or other grounded connector
using twist-on connector. (See Figure 3.)
Do Not connect
bare ground wire to neutral
(white) wire in junction
box.
B=
Where local codes permit connecting
the frame-ground
conductor to the neutral
(white) junction box wire. (Not used for
Canadian installations):
3=wire cable from
junction
power supply
box
black
wires
white and bare
grounding oven cable
wires = factory crimped
U.L.- or ¢,S.A.= Hsted
conduit
connector
4-wire cable from cooktop
Grounded
neutral
Figure
4
1. Follow steps 1 and 2 from "A" above.
2. Connect the two black wires together; the two
red wires together; and the factory-crimped
bare and white cooktop cable wires to the
white (neutral) wire in the junction box using
twist-on connectors. (See Figure 4.)
C
B Where local codes Do Not permit
connecting
the frame=ground
conductor
to
the neutrat (white) junction
box wire:
1. Follow steps 1 and 2 from "A" above.
2. Connect the two black wires together and the
two red wires together.
3. Separate the factory=crimped bare and white
cooktop cable wires.
4. Connect the two white wires together using
twist=on connectors.
5. Connect the bare ground wire from the
cooktop cable to a grounded wire in the
junction box or other grounded connector
using twist=on connector. (See Figure 3.)
Do Not connect
bare ground wire to neutrat
(white) wire in junction
box.