2.1 Connect the 1" Coolant return
hose to Coolant Outlet port by
using the large hose clamp.
5. 1The bracket that holds the float tubes must attach on the edge of coolant tank, in
order to keep it away from the existing chips or debris.
suspended solids or floating debris on the surface of the coolant, be sure to
remove them before operating the unit.
6. 1The Float Tube Inlet must face in the upward position.
7. 1In order to keep the Inlet on the surface of coolant, adjust the bracket that retains
the float inlet accordingly to an appropriate position.
To keep the float tubes balanced, the coolant level must be maintained above 2" if
required, please add coolant.
Installation Guide – Page 2
4. 1 Connect Air supply hose
3.1 Connect the Coolant Inlet hose to the
Coolant Inlet port using small hose clamp
If there are any