Century CJW2000 SERIES Panduan Pemilik - Halaman 9
Jelajahi secara online atau unduh pdf Panduan Pemilik untuk Kompor kayu Century CJW2000 SERIES. Century CJW2000 SERIES 17 halaman. High efficiency air tight wood stove
REFER TO CHIMNEY AND CHIMNEY CONNECTOR MANUFACTURER'S INSTRUCTIONS
CHIMNEY
CONTACT YOUR LOCAL BUILDING
AUTHORITY FOR APPROVED METHODS
OF INSTALLATION
1. This appliance requires a masonry or pre-
manufactured chimney listed to ULC
S629 (Canada) and UL103HT (USA)
sized correctly.
2. If a masonry chimney is used it is
advisable to have your chimney
inspected for cracks and check the
general condition before you install your
unit Re-lining may be required to reduce
flue diameter to the appropriate functional
size.
3. To help ensure a good draft, the top of the
chimney should be at least 3 feet
(914mm) above the point of penetration
through the roof, and be at least 2
(610mm) feet higher than any point of the
roof within 10 feet (3M).
4. The chimney connector shall not pass through an attic, roof space, closet, concealed space,
floor, ceiling, wall, or any partition of combustible construction.
5. The minimum overall height of your chimney should be 15 feet (5M) from the floor.
6. Do not use makeshift compromises during installation.
OPERATION
Do not use a grate or elevate fire. Build wood fire directly on hearth. When the stove is used for
the first time the solvents in the paint will smoke off.
Wood
This heater is designed to burn natural wood only. Higher efficiencies and lower emissions
generally result when burning air dried seasoned hardwoods, as compared to softwoods or to
green or freshly cut hardwoods.
Only use dry seasoned wood. Green wood, besides burning at only 60 percent of the fuel value of
dry wood, deposits creosote on the inside of your stove and along the chimney. This can cause an
extreme danger of chimney fire. To be called "seasoned", wood must be dried for a year.
Regardless of whether the wood is green or seasoned, it should be stored in a well-sheltered,
ventilated area to allow proper drying during the year to come. Wood should be stored beyond
recommended clearance from combustibles.
*
DO NOT BURN:
*
Garbage
*
Treated Wood
Solvents
*
Cardboard
3FT(1M) MIN
FROM ROOF
PENETRATION
MINIMUM OVERALL
HEIGHT FROM FLOOR
15FT(5M)
*
Trash
*
Coloured Papers
9
2FT(610mm) HIGHER
THAN NEAREST
POINT OF ROOF
WITHIN 1OFT(3m)
*
Coal